Overview
Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Specs at a glance
* Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
–50 to +150 °C (–58 to +302 °F)
* Max. process pressure
PN 40, Class 150, 20K
* Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
–50 to +150 °C (–58 to +302 °F)
* Max. process pressure
PN 40, Class 150, 20K
* Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Application
Promass S is at the forefront in hygienic design and dedicated to applications in the food and beverage industry requiring optimal cleanability. The self‐drainable single-tube system ensures careful treatment of fluids. With its innovative remote transmitter Promass S 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables process safety at all times.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Dedicated to applications requiring optimal cleanability under hygienic conditions
Device properties
* Large range of hygienic process connections
* 3-A and EHEDG conform
* Fast recovery from CIP/SIP
* Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Dedicated to applications requiring optimal cleanability under hygienic conditions
Device properties
* Large range of hygienic process connections
* 3-A and EHEDG conform
* Fast recovery from CIP/SIP
* Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter
Benefits
* Increased process safety – easily cleanable and fully self-drainable tube design
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Promass S500
|
Type
|
Coriolis meters, Coriolis flowmeter
|
Material
|
316/316L
|
Product Headline
|
Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Dedicated to applications requiring optimal cleanability under hygienic conditions. |
Sensor Features
|
Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable
measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP. |
Transmitter features
|
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and
variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range
|
DN 8 to 50 (⅜ to 2")
|
Wetted Materials
|
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured Variables
|
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
Max. Measurement Error
|
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 % Density (liquid): ±0.0005 g/cm³ |
Measuring Range
|
0 to 70 000 kg/h (0 to 2570 lb/min)
|
Max. Process Pressure
|
PN 40, Class 150, 20K
|
Medium Temperature Range
|
–50 to +150 °C (–58 to +302 °F)
|
Ambient Temperature Range
|
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) |
Sensor Housing Material
|
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
Transmitter Housing Material
|
AlSi10Mg, coated; Polycarbonat
|
Degree Of Protection
|
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation
|
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible |
Outputs
|
4 outputs:
4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs
|
Status input
4-20 mA input |
Digital Communication
|
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
|
Power Supply
|
DC 24 V
AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous Area Approvals
|
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
|
Product Safety
|
CE, C-Tick, EAC marking
|
Functional Safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological Approvals And Certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure Approvals And Certificates
|
PED, CRN
|
Material Certificates
|
3.1 material
|
Hygienic Approvals And Certificates
|
3‐A, EHEDG, cGMP
|
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.