Overview
Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m
Specs at a glance
* Accuracy
+/- 2 mm or +/- 0,2 % of set measuring range
* Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
* Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
* Max. measurement distance
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)
* Main wetted parts
PVDF
+/- 2 mm or +/- 0,2 % of set measuring range
* Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
* Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
* Max. measurement distance
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)
* Main wetted parts
PVDF
Application
The Prosonic FMU41 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks,agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis.Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Two-wire or four wire instrument for continuous non-contact level and flow measurement.
* Process connection: Thread
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: +0.7 to +3bar (+10 to +44psi)
* Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft)
* Blocking distance: Liquids and Solids 0.35m (1.15ft)
* International explosion protection certificates
Two-wire or four wire instrument for continuous non-contact level and flow measurement.
* Process connection: Thread
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: +0.7 to +3bar (+10 to +44psi)
* Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft)
* Blocking distance: Liquids and Solids 0.35m (1.15ft)
* International explosion protection certificates
Benefits
* Reliable non-contact measurement
* Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
* Envelope curves on the on-site display for simple diagnosis
* Hermetically sealed and potted sensor
* Chemically resistant sensor out of PVDF
* Calibration without filling or discharging
* Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
* Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
* Envelope curves on the on-site display for simple diagnosis
* Hermetically sealed and potted sensor
* Chemically resistant sensor out of PVDF
* Calibration without filling or discharging
* Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
endress+hauser
|
Model Number
|
Prosonic FMU41
|
Material
|
PVDF
|
Mode
|
Ultrasonic measurement Time-of-Flight
|
Measuring Principle
|
Ultrasonic
|
Characteristic / Application
|
Compact ultrasonic transmitter
|
Supply / Communication
|
2-wire HART
|
Accuracy
|
+/- 2 mm or +/- 0,2 % of set measuring range
|
Ambient Temperature
|
-40 °C ... 80 °C
(-40 °F ... 176 °F) |
Process Temperature
|
-40 °C ... 80 °C
(-40 °F ... 176 °F) |
Process Pressure / Max. Overpressure Limit
|
0.7 bar ... 3 bar abs
(10 psi ... 44 psi) |
Main Wetted Parts
|
PVDF
|
Process Connection
|
G / NPT 2"
|
Blocking Distance
|
0.35 m (1.15 ft)
|
Max. Measurement Distance
|
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft) |
Communication
|
4...20 mA HART
|
Certificates / Approvals
|
ATEX, FM, CSA, TIIS, INMETRO, NEPSI
|
Application Limits
|
For higher resistance:
FMU42/FDU9x Foam / high turbulence possible: FMU42/FDU91 Fast filling and discharging rate: FMU90 + FDU9x Level limit detection: FMU90 + FDU9x |
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.