Endress+hauser Temperature Sensor iTHERM ModuLine TM101

: В наличии

: Temperature Meaurement

: Endress+Hauser

Обычная цена Распродажа

Overview  Endress+hauser iTHERM ModuLine TM101 TEMPERATURE SENSOR  Application Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert...

Overview 

Endress+hauser iTHERM ModuLine TM101 TEMPERATURE SENSOR 

Application

Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.

*Wide range of applications *Measuring range: -50 to +650 °C (-58 to +1202 °F) 

*Pressure range: up to 50 bar (725 psi)

*Protection class: up to IP68

*For use in non-hazardous areas

Benefits

*Excellent value for money and fast global delivery 

*User-friendly product selection, smart design for easy maintenance

*Wide range of process connections

*Bluetooth® connectivity (optional)

Specification 

Measuring principle

Resistance Temperature Detector

Characteristic / Application

Basic technologie
metric style
universal range of application
direct process contact

Thermowell / protection tube

without, direct process contact

Insert / probe

Basis Sensortechnologie

Outer diameter protection tube / Insert 

Insert: 6,0 mm

Max. immersion length on request

up to 1.000,0 mm (39'')

Material protection tube/ thermowell

Insert Material:
316L (1.4404)
Alloy 600 (2.4816)

Process connection

 Thread:
G1/2", G1/4"
NPT1/2"
M18x1.5, M20x1.5
Cap-nut:
G1/2", G3/4"
Compression fitting, also spring load:
NPT1/2", G1/2"

Tip shape

 straight

Operating temperature range

 Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)

Max. process pressure (static)

 depending on the configuration

Accuracy

Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2

Response time

t90 around 17 s
depending on configuration

Integration head transmitter

yes (4 … 20 mA; HART)

 