Overview
For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
Specs at a glance
Accuracy
class A acc. to IEC 60751
Response time
depending on configuration
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. immersion length on request
up to 400 mm (15,75")
Field of application
This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.
Benefits
* Excellent value for money and fast delivery
* User-friendly and reliable from product selection to maintenance
* International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
* Wide range of process connections
* User-friendly and reliable from product selection to maintenance
* International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
* Wide range of process connections
* Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
* Measuring range: –50 to +200 °C (–8 to +392 °F)
* Pressure range up to 50 bar (725 psi)
* Protection class: up to IP69K
* Can be used in non-hazardous areas
* Measuring range: –50 to +200 °C (–8 to +392 °F)
* Pressure range up to 50 bar (725 psi)
* Protection class: up to IP69K
* Can be used in non-hazardous areas
Specification
Brand Name
|
ENDRESS+HAUSER
|
Model Number
|
TM401
|
Theory
|
Temperature Transmitter
|
Material
|
316L
|
Type
|
Temperature Transmitter
|
Measuring range
|
-50 to +200 °C (-8 to +392 °F)
|
Pressure range
|
up to 50 bar (725 psi)
|
Protection class
|
up to IP69K
|
Max. process pressure (static)
|
at 20 °C: 40 bar (580 psi)
|
Operating temperature range
|
PT100: -50 °C ... 200 °C (-58 °F ... 392 °F)
|
Max. immersion length on request
|
up to 400 mm (15,75")
|
Measuring principle
|
Resistance Temperature Detector
|
Characteristic / Application
|
metric style
hygienic applications aseptic applications hygienic process connections with neck |
Thermowell / protection tube
|
without (not intended to use with thermowell)
|
Insert / probe
|
without exchangeable insert
|
Outer diameter protection tube / Insert
|
6,0 mm (0,24")
8,0 mm (0,31") |
Max. immersion length on request
|
up to 400 mm (15,75")
|
Material protection tube/ thermowell
|
316L
|
Process connection
|
compression fitting
triclamp microclamp clamp connections acc. to ISO2852 Ingold G3/4" Liquiphant G1" Liquiphant Varivent SMS 1147 screwed pipe joint acc. to DIN 11851 |
Tip shape
|
straight
reduced |
Surface roughness Ra
|
0,76 μm (30 μin)
0,38 μm (15 μin) |
Operating temperature range
|
PT100:
-50 °C … 200 °C (-58 °F … 392 °F) |
Accuracy
|
class A acc. to IEC 60751
|
Integration head transmitter
|
yes (4 ... 20 mA, HART)
|
Certification
|
SIL (transmitter only)
|
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.