Overview SITRANS FX Vortex flowmeter are designed for use in industrial applications and optimally suited to the demands in auxiliary supply systems.The proven principle of vortex flowmeters is suitable...

Overview

SITRANS FX Vortex flowmeter are designed for use in industrial applications and optimally suited to the demands in auxiliary supply systems.The proven principle of vortex flowmeters is suitable for measurement of liquids, gases and vapors unaffected by conductivity,viscosity, temperature and pressure.

Benefits

* Integrated pressure and temperature compensation
* Temperature compensation for saturated steam included as standard
* High measuring accuracy
* Maintenance-free sensor
* Non-wearing, fully welded stainless steel construction with high resistance to corrosion, pressure and temperature
* SIL2 certified according to IEC 61508 Edition 2
* Use in hazardous areas
* Integrated reduction of nominal diameter for space-saving and economic installation and large measuring ranges
* Redundant data management: Easy exchange of electronics without loss of calibration and configuration data
* FAD (Free Air Delivery) functionality
* Gross and net heat calculation to support advanced energy management
* Remote version with cable length up to 50 m (164 ft)
Even the basic version of the vortex flowmeter SITRANS FX330 is equipped with temperature compensation for saturated steam applications. With the optional pressure sensor the SITRANS FX330 has integrated density compensation for calculation of corrected volume and mass (online density compensation). The density compensation for calculation of corrected volume and mass is based on the standards of NIST for gases and IAPWS for steam.

Application

* Measurement of saturated steam and superheated steam
* Steam boiler monitoring
* Heat metering of steam and hot water
* Measurement of consumption of industrial gases
* Measurement of consumption in compressed air systems
* Monitoring of compressor output
* Evaluation of Free Air Delivery (FAD)
* SIP and CIP processes in the food, beverage and pharmaceutical industries
* Measuring of conductive and non-conductive liquids
* Safety-related measurement in SIL applications (SIL2)

Design

SITRANS FX330 Flange
Flange version with integrated temperature compensation as standard for saturated steam and optional pressure compensation for superheated steam, gases and wet gases.
Integrated reduction of nominal diameter for space-saving and economic installations plus large measuring ranges.Also in remote design with field housing and connection cable up to 50 m (164 ft).With shut off valve allowing
* exchange and calibration of pressure sensor
* pressure and leak testing of pipeline without interrupting the process
SITRANS FX330 Sandwich
All advantages of the flange version in a space-saving sandwich design; centering rings guarantee an easy installation without any offset.
Integrated reduction of nominal diameter not available.
Also in remote design with field housing and connection cable up to 50 m (164 ft).
With shut off valve allowing
* exchange and calibration of pressure sensor
* pressure and leak testing of pipeline without interrupting the process

Function

Vortex flowmeters are used to measure the flow of gases, vapors and liquids in completely filled pipes. The measuring principle is based on the principle of the Karman vortex street. Inside the measuring sensor vortices are shed from a bluff body and are detected by a sensor located behind. The frequency f of the vortex shedding is proportional to the flow velocity v.The nondimensional Strouhal number S describes the relationshipbetween vortex frequency f, width b of the bluff body and the mean flow velocity v:f = (S · v) / b
The vortex frequency is recorded at the sensor and evaluated at the converter.

Specification

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
SIEMENS
Model Number
FX330
Type
Vortex Flowmeter
Nominal Size Flanged Version
DN15 to DN300 (1/2" to 12")
Nominal Size Sandwich Version
DN15 to DN100 (1/2" to 4")
Process Alues
Volume flow, mass flow, corrected volume flow, density, temperature, pressure, heat energy
Accuracy
Steam and gases: +/- 1% 
 Liquids: +/- 0.75%
Current Output
4 - 20 mA HART (loop powered)
Digital Output
Pulse (max. 1000 Hz), frequency, status, limit switch
Communication
HART 7, Profibus PA and Foundation Fieldbus in preparation
Pressure Rating
PN 10 ~ 100; Class 150 - 600
Medium Temperature
-40 ... 240 °C (-40 ... 464 °F)
Material Sensor
Stainless steel 1.4404 (316L), Hastelloy C22 on request
Transmitter Enclosure
Die-cast aluminium
Enclosure Rating
IP66 / 67 (NEMA 6)
Connection
EN 1092-1; ASME B16.5
Wafer design (centering rings included)
Remote Transmitter
Connection cable up to 50m (164 ft), remote version in preparation
Temperature Sensor
Standard integrated temperature sensor
Pressure Sensor
Optional integrated pressure sensor with or without isolation valve
Display And Keypad
High-resolution graphical display and 4 operating keys (alternative use magnet pen)
Ex Approvals
ATEX II2 G Ex ia - QPS IS Class I Div.1 - IECEx II2 G Ex ia
ATEX II2 G Ex d - QPS XP Class I Div.1 - IECEx II2 G Ex d
ATEX II3 G Ex nA - QPS NI Class I Div. 2 - IECEx II3 G Ex nA
ATEX II2 D Ex tb - QPS DIP Class II, III Div. 1 - IECEx II2 D Ex tb
Safety Integration Level (SIL)
SIL2 according to IEC 61508
Application Examples
chemical, power, and oil and gas installations