Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 10m.
Specs at a glance
* Accuracy
+/- 4 mm or +/- 0,2 % of set measuring range
* Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
* Process pressure / max. overpressure limit
0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)
* Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft)
* Main wetted parts
PVDF
+/- 4 mm or +/- 0,2 % of set measuring range
* Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
* Process pressure / max. overpressure limit
0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi)
* Max. measurement distance
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft)
* Main wetted parts
PVDF
Application
The Prosonic FMU42 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks,
agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate. Two-wire or four wire instrument for continuous non-contact level and flow measurement.
* Process connection: Flange
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: +0.7 to +2.5bar (+10 to +36psi)
* Maximum measuring distance: Liquids 10m (33ft), Solids 5m (16ft)
* Blocking distance: Liquids and Solids 0.4m (1.3ft)
* International explosion protection certificates
agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate. Two-wire or four wire instrument for continuous non-contact level and flow measurement.
* Process connection: Flange
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: +0.7 to +2.5bar (+10 to +36psi)
* Maximum measuring distance: Liquids 10m (33ft), Solids 5m (16ft)
* Blocking distance: Liquids and Solids 0.4m (1.3ft)
* International explosion protection certificates
Benefits
* Reliable non-contact measurement
* Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
* Envelope curves on the on-site display for simple diagnosis
* Hermetically sealed and potted sensor
* Chemically resistant sensor out of PVDF
* Calibration without filling or discharging
* Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
* Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
* Envelope curves on the on-site display for simple diagnosis
* Hermetically sealed and potted sensor
* Chemically resistant sensor out of PVDF
* Calibration without filling or discharging
* Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
endress+hauser
|
Model Number
|
Prosonic FMU42
|
Material
|
PVDF
|
Mode
|
Ultrasonic measurement Time-of-Flight
|
Measuring Principle
|
Ultrasonic
|
Characteristic / Application
|
Compact ultrasonic transmitter
|
Supply / Communication
|
2-wire HART
|
Accuracy
|
+/- 4 mm or +/- 0,2 % of set measuring range
|
Ambient Temperature
|
-40 °C ... 80 °C
(-40 °F ... 176 °F) |
Process Temperature
|
-40 °C ... 80 °C
(-40 °F ... 176 °F) |
Process Pressure / Max. Overpressure Limit
|
0.7 bar ... 2.5 bar abs
(10 psi ... 36 psi) |
Main Wetted Parts
|
PVDF
|
Process Connection
|
Flange
DN80, ASME 3", JIS 10K 80 DN100,ASME 4", JIS 10K 100 Mounting bracket |
Blocking Distance
|
0.4 m (1.3 ft)
|
Max. Measurement Distance
|
Liquids: 10 m (33 ft),
Solids: 5 m (16 ft) |
Communication
|
4...20 mA HART
|
Certificates / Approvals
|
ATEX, FM, CSA, INMETRO, NEPSI
|
Application Limits
|
Foam / high turbulence possible:
FMU44/FDU92 Fast filling and discharging rate: FMU90 + FDU9x Level limit detection FMU90 + FDU9x |
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.