Specs at a glance

* Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 800 000 kg/h (0 to 29 400 lb/min)
* Medium temperature range
–40 to +205 °C (–40 to +401 °F)
* Max. process pressure
PN 250, Class 1500
* Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) 
 

Field of application

Promass O is designed for premium accuracy of liquids and gases at the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. With its innovative remote transmitter Promass O 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables safe processes.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* For premium accuracy at highest process pressures, fully suitable for offshore conditions


Device properties
* Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750)
* Process pressure up to PN 250 (Class 1500)
* Nominal diameter: DN 80 to 250 (3 to 10")
* Remote version with up to 4 I/Os
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter

Benefits

 * Maximum safety – highest resistance to stress corrosion cracking
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology 
 

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Switzerland
Brand Name Endress+Hauser
Model Number Promass O500
Type Coriolis meters, Coriolis flowmeter
Measuring Principle 
 
Coriolis
Product Headline Robust high-pressure flowmeter, as remote version with up to 4 I/Os. 
For premium accuracy at highest process pressures, fully suitable for offshore conditions.
Sensor Features Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement 
(flow, density, temperature). Space‐saving installation – no in-/outlet run needs. 
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 
to 10").
Transmitter Features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and 
variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. 
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and 
transmitter.
Nominal Diameter Range DN 80 to 250 (3 to 10")
Wetted Materials Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) 
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)
Measured Variables Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration
Max. Measurement Error Mass flow (liquid): ±0.1 (standard), 0.05 % (option) 
Volume flow (liquid): ±0.1 % 
Mass flow (gas): ±0.35 % 
Density (liquid): ±0.0005 g/cm³
Measuring Range 0 to 2 200 000 kg/h (0 to 80 850 lb/min)
Max. Process Pressure PN 250, Class 1500
Medium Temperature Range –40 to +205 °C (–40 to +401 °F)
Ambient Temperature Range Standard: –40 to +60 °C (–40 to +140 °F) 
Option: –50 to +60 °C (–58 to +140 °F)
Sensor Housing Material 1.4404 (316L), highest corrosion resistance 
Sensor connection housing (standard): AlSi10Mg, coated 
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter Housing Material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree Of Protection Sensor remote version (standard): IP66/67, type 4X enclosure 
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible
Outputs 4 outputs: 
4-20 mA HART (active/passive) 
4-20 mA WirelessHART 
4-20 mA (active/passive) 
Pulse/frequency/switch output (active/passive) 
Double pulse output (active/passive) 
Relay output
Inputs Status input 
4-20 mA input
Digital Communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power Supply DC 24 V 
AC 100 to 230 V 
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product Safety CE, C-tick, EAC marking
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation) 
MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG 
OIML R117 Liquids other than water, Cryogenic Liquids, LPG 
MI-002, PTB
Marine Approvals And Certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure Approvals And Certificates PED, CRN, AD 2000
Material Certificates 3.1 material 
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

 