Overview  Differential pressure transmitter with metal sensor for measurement of pressure differences. Specs at a glance * AccuracyStandard: 0.05%Platinum: up to 0.035%* Max. measurement error0,075%"PLATINUM" 0,05%* Process temperature-40...


Overview 

Differential pressure transmitter with metal sensor for measurement of pressure differences.
Specs at a glance
* Accuracy
Standard: 0.05%
Platinum: up to 0.035%
* Max. measurement error
0,075%
"PLATINUM" 0,05%
* Process temperature
-40 °C...85 °C
(-40 °F...185 °F)
* Medium temperature range
Temperature gradient from pressure piping
* Pressure measuring range
10 mbar...250 bar
(0.15 psi...3750 psi)
* Process pressure / max. overpressure limit
420 bar (6300 psi)
* Main wetted parts
Alloy C276
316L
Monel
Tantalum
* Max. measurement distance
400 m (1.312 ft) H2O
* Max. process pressure
max. 420 bar
(max. 6091 psi)
* Material process membrane
316L, AlloyC,
Tantal,
Gold-Rhodium
* Measuring cell
10 mbar...250 bar
(0.15 psi...3750 psi)

Application

The Deltabar PMD75 differential pressure transmitter with piezoresistive sensor and welded metallic membrane is used in all industries for continuous measurement in liquids, vapors and gases. The 3-key operation enables simple and reliable commissioning and operation. The integrated HistoROM data module allows easy management of process and device parameters. Designed according to
IEC 61508 for use in SIL2/3 safety applications.

For level, volume or mass measurement in liquids, differential pressure monitoring as well as flow measurement (volume or mass flow) in conjunction with primary elements in gases, vapors and liquids.
* Process connections: Threads
* Process temperature: -40 to +85°C (-40 to +185°F)
* Measuring ranges: 0.25mbar to 40bar (0.0036 to 600psi)
* Accuracy: ±0.05%, "Platinum" ±0.035% (optional)
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

Benefits

* Best accuracy, reproducibility and long-term stability
* Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Cost savings with modular concept for easy replacement of sensor, display or electronics
* Overload-resistant up to 420bar / 42MPa / 6300psi, function-monitored
* Seamless and independent system integration (HART/PA/FF)

Specification 

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Deltabar PMD75
Material
316L, Die-cast aluminum
Measuring Principle
Differential pressure
Characteristic
Digital transmitter with metallic measuring diaphragms
Modular transmitter
Long-term stability
High static pressure/Overload resistance
Secondary process barrier
Supply Voltage
4...20 mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy
Standard: 0.05%
Platinum: up to 0.035%
Long Term Stability
0.03 % of URL/ year
0.05 % of URL/ 5 years
0.08 % of URL/ 10 years
Process Temperature
-40°C...85°C
(-40°F...185°F)
Ambient Temperature
-50°C...85°C
(-58°F...185°F)
Measuring Cell
10 mbar...250 bar
(0.15 psi...3750 psi)
Smallest Calibratable Span
1 mbar (0.015 psi)
Vacuum Resistance
50 mbar (0.73 psi)
Max. Turn Down
100:1
Max. Overpressure Limit
On one side:
420 bar
(6300psi)
Process Connection
1/4-18NPT
RC1/4"
Material Process Membrane
316L, AlloyC,
Tantal,
Gold-Rhodium
Material Gasket
Viton, PTFE, EPDM, NBR
Fill Fluid
Silicone oil
Inert oil
Material Housing
316L, Die-cast aluminum
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety Approvals
SIL
Design Approvals
NACE MR0103
EN10204-3.1
Marine Approvals
GL/ ABS
Specialities
Diagnostic functions
Successor
PMD75B