Endress+Hauser Proline Promag 55S Electromagnetic Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

Overview The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics. Specs at a glance * Max. measurement errorVolume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)Option:...


Overview

The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.

Specs at a glance

* Max. measurement error
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
* Measuring range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
* Medium temperature range
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to
+150 °C (–4 to +266 °F)
* Max. process pressure
PN 40, Cl. 300, JIS 20 K
* Wetted materials
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum

Application

Promag S is the specialist for inhomogeneous, abrasive and corrosive fluids. The robust sensor design, featuring industry-optimized liners, enables its use in most challenging surroundings and metering jobs such as sewage treatment, pulp and paper production or in the primaries and metals industry. Due to its high-performance transmitter, Promag 55S not only measures flow reliably, but also calculates solids content at low maintenance requirements.

* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
* Ideal for the most demanding applications with high solids content and high abrasion.

Device properties
* Intensified coil system
* Large range of liners
* Solids content up to 80 % by weight
* 4-line backlit display with touch control
* Two switch outputs
* HART, PROFIBUS PA/DP, FOUNDATION Fieldbus

Benefits

* Superb signal stability due to unique signal processing
* Maximum safety – industry-optimized measuring electrodes and linings
* Energy-saving flow measurement – no pressure loss due to cross-section constriction
* Maintenance-free – no moving parts
* Highest performance – with integrated solids measurement for demanding fluids
* Highest safety – integrated electrode cleaning
* Automatic recovery of data for servicing

Specification

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Proline Promag 55S
Type
Electromagnetic flowmeter
Product Headline
The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.
Superb signal stability due to unique signal processing.
Ideal for the most demanding applications with high solids content and high abrasion.
Sensor Features
Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to
cross section constriction. Maintenance‐free – no moving parts.
Intensified coil system. Large range of liners. Solids content up to 80 % by weight.
Transmitter Features
Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning.
Automatic recovery of data for servicing.
4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
Nominal Diameter Range
DN 15...600
1/2"...24"
Wetted materials
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Measured variables
Volume flow, electrical conductivity, mass flow
Max. Measurement Error
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring Range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Max. Process Pressure
PN 40, Cl. 300, JIS 20 K
Medium Temperature Range
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to
+150 °C (–4 to +266 °F)
Ambient Temperature Range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
Aluminum coated AlSi10Mg, carbon steel with protective varnish
Transmitter housing material
Powder-coated die-cast aluminum
Degree Of Protection
Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor
Display/Operation
Liquid-crystal display: illuminated, four lines with 16 characters per line
Onsite operation with three optical sensor keys
Outputs
4...20mA
(active/passive) Pulse-/ Frequency output (active/passive)
Two status outputs
Inputs
Status
Current input
Digital Communication
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Power supply
AC 20 to 260 V
DC 20 to 64 V
Hazardous area approvals
ATEX, FM, CSA, UK Ex
Product Safety
CE, C-tick, EAC marking
Pressure approvals and certificates
CRN, PED
Material certificates
3.1 material
Hygienic approvals and certificates
Drinking water approval:ACS, KTW/W270, NSF 61, WRAS BS 6920


please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.