Overview
Endress+Hauser Proline Prosonic I400 Ultrasonic Flowmeter is an insertion flowmeter with Heartbeat Technology and web server for the water and wastewater industry.
Specs at a glance
* Max. measurement error
Volume flow: ±2% o.r. above DN200
* Measuring range
0 to 15 m/s (0 to 50 ft/s)
* Medium temperature range
–40 to +80 °C (–40 to +176 °F)
* Max. process pressure
N/A
* Wetted materials
Insertion system:
Sensor holder 1.4301 (304), 1.4404 (316L)
Sensor housing 1.4301 (304), 1.4404 (316L)
Field of application
Prosonic Flow I 400 combines insertion sensor technology with the benefits of our Proline 400 transmitters, such as Heartbeat Technology for safe process monitoring and web server access for easy installation and operation. Welded directly into the pipe wall, Prosonic Flow I 400 is especially suitable for large pipelines such as water distribution lines and projects where a fixed device installation is necessary.
* The measuring principle is independent of density and conductivity
* Bidirectional flow measurement of water and wastewater
Device properties:
* Supports two parallel measurement paths
* For large diameters: DN 200 to 4000 (8 to 160")
* Medium temperatur: –40 to +80 °C (–40 to +176 °F)
* Transmitter housing made of durable polycarbonate or aluminium
* Remote version for wall mounting
* Integrated data logger: measured values
Benefits
* Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 4000/160")
* Long-term stable signal – maintenance-free direct installation of the sensor into the medium
* Process transparency – diagnostic capability
* Safe operation – no need to open the device due to display with touch control, background lighting
* Full remote access – web server
* Integrated diagnostics, verification and monitoring – Heartbeat Technology
Specification
item | value |
Warranty | 1 Year |
Customized support | OEM |
Place of Origin | Germany |
Brand Name | Endress+Hauser |
Model Number | Prosonic Flow I400 |
Type | Ultrasonic flow meters |
Product Headline | Insertion meter with Heartbeat Technology and web server for the water and wastewater industry. Bidirectional flow measurement of water and wastewater. |
Sensor Features | Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability. Supports two parallel measurement paths. For large diameters: DN 200 to 4000 (8 to 160"). Medium temperatur: –40 to +80 °C (–40 to +176 °F). |
Transmitter Features | Safe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring. |
Nominal Diameter Range | DN200 to 4000 (8 to 160") |
Wetted Materials | Insertion system: Sensor holder 1.4301 (304), 1.4404 (316L) Sensor housing 1.4301 (304), 1.4404 (316L) |
Measured Variables | Volume flow, Flow velocity, Sound velocity |
Max. Measurement Error | Volume flow: ±2% o.r. above DN200 |
Measuring Range | 0 to 15 m/s (0 to 50 ft/s) |
Max. Process Pressure | N/A |
Medium Temperature Range | –40 to +80 °C (–40 to +176 °F) |
Ambient Temperature Range | -20 to 60°C (-4 to 140°F) |
Sensor Housing Material | N/A |
Transmitter Housing Material | Wall-mounted housing: Polycarbonat; AlSi10Mg, coated |
Degree Of Protection | Transmitter: IP66/67, Type 4X enclosure Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional) |
Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display, web browser and operating tools possible |
Outputs | 3 ouputs: 4‐20 mA/4‐20 mA HART (active) Pulse/frequency/switch output (passive) Pulse/frequency/switch output (passive) |
Inputs | Status input |
Digital Communication | HART |
Power Supply | AC 100 to 240 V / AC/DC 24 V |
Approvals | cCSAus |
Product Safety | CE, C-tick marking, EAC-marking |
Metrological Approvals And Certificates | Flowmeter verification Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a |
Marine Approvals And Certificates | Marine approvals and certificates |
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.