Endress+Hauser 5HBB Proline Promag H10 Electromagnetic Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress+Hauser Proline Promag H10 Electromagnetic Flowmeter is a flowmeter for basic hygienic applications with easy-to-use operation concept.Specs at a glanceMax. measurement error Volume flow (standard): ±0.5 % o.r....

Overview

Endress+Hauser Proline Promag H10 Electromagnetic Flowmeter is a flowmeter for basic hygienic applications with easy-to-use operation concept.

Specs at a glance

Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) Measuring range 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min) Medium temperature range –20 to +150 °C (–4 to +302 °F) Max. process pressure PN 40, Class 150, 20K Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)

Application

Promag H is the preferred sensor for hygienic applications in the food and beverage and life sciences industries. With its straightforward hard- and software design, Promag H 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
* For applications with sanitary requirements.


Device properties
* Liner made of PFA
* Sensor housing made of stainless steel (3-A, EHEDG)
* Wetted materials CIP-/SIP-cleanable
* System integration with HART, Modbus RS485
* Flexible operation with app and optional display 
 

Benefits

* Flexible installation concept – numerous hygienic process connections
* Energy-saving flow measurement – no pressure loss due to cross section constriction
* Maintenance-free – no moving parts
* Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen
* Simple, time-saving commissioning – guided parameterization in advance and in the field
* Integrated verification – Heartbeat Technology

Specification

Model Number Proline Promag H 10
Measuring principle Electromagnetic 
 
Product headline Flowmeter for basic hygienic applications with easy-to-use operation concept. 
For applications with sanitary requirements.
Sensor features Flexible installation concept – numerous hygienic process connections. Energy-saving flow measurement – no pressure loss due to 
cross section constriction. Maintenance-free – no moving parts. 
Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). Wetted materials CIP-/SIP-cleanable.
Transmitter features Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and 
SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – 
Heartbeat Technology. 
System integration with HART, Modbus RS485, IO-Link. Flexible operation with app and optional display.
Nominal diameter range DN 2 to 150 (¹⁄₁₂ to 6")
Wetted materials Liner: PFA 
Electrodes: 1.4435 (316L); Alloy C22 
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve 
Seals: aseptic molded seal (EPDM, FKM, silicone)
Measured variables Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected 
conductivity
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Measuring range 0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –20 to +150 °C (–4 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection Standard: IP66/67, type 4X enclosure
Display/Operation 2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible
Outputs 4-20 mA HART (active/passive), Pulse/frequency/switch output 
Modbus RS485, 4-20 mA
Digital communication HART, MODBUS RS485
Power supply DC 24 V 
AC 100 to 230 V 
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals CSA, GP, KC
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP

 

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,