Overview
Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids.
Specs at a glance
* Accuracy
0,075% + influence of diaphragm seal
* Process temperature
-70°C...400°C
(-94°F...752°F)
* Pressure measuring range
400 mbar...400 bar
(5.8 psi...6000 psi)
* Process pressure / max. overpressure limit
1050bar (15,200psi)
* Main wetted parts
Alloy C276
316L
Monel
Tantalum
PTFE-Foil
* Max. measurement distance
7000m (22.966ft) H2O
* Material process membrane
316L, AlloyC,
Tantal
Rhodium> Gold
PTFE
* Measuring cell
400 mbar...400 bar
(5.8 psi...6000 psi)
relative/ absolute
0,075% + influence of diaphragm seal
* Process temperature
-70°C...400°C
(-94°F...752°F)
* Pressure measuring range
400 mbar...400 bar
(5.8 psi...6000 psi)
* Process pressure / max. overpressure limit
1050bar (15,200psi)
* Main wetted parts
Alloy C276
316L
Monel
Tantalum
PTFE-Foil
* Max. measurement distance
7000m (22.966ft) H2O
* Material process membrane
316L, AlloyC,
Tantal
Rhodium> Gold
PTFE
* Measuring cell
400 mbar...400 bar
(5.8 psi...6000 psi)
relative/ absolute
Field of application
The Cerabar PMP75 digital pressure transmitter with metal diaphragm seal is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. Suitable for high pressure as well as extreme process temperature applications from -70 up to +400°C (-94 to 750°F). Quick Setup with adjustable measuring range allows simple commissioning,
reduces costs and saves time. Designed according to IEC 61508 for use in SIL2/3 safety applications.
Two chamber aluminum or stainless steel (316L) housing.
* Process connections: Threads, flanges or hygienic connections
* Process temperature: -70 to +400°C (-94 to +752°F)
* Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
reduces costs and saves time. Designed according to IEC 61508 for use in SIL2/3 safety applications.
Two chamber aluminum or stainless steel (316L) housing.
* Process connections: Threads, flanges or hygienic connections
* Process temperature: -70 to +400°C (-94 to +752°F)
* Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
Benefits
* Large variety of different process connections and membrane materials
* New TempC Membrane minimizes influences of ambient and process temperature fluctuations
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
* Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
* Cost savings with modular concept for easy replacement of sensor, display or electronics
* Overload-resistant and function-monitored from the measuring cell to the electronics
* New TempC Membrane minimizes influences of ambient and process temperature fluctuations
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
* Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
* Cost savings with modular concept for easy replacement of sensor, display or electronics
* Overload-resistant and function-monitored from the measuring cell to the electronics
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Cerabar PMP75
|
Measuring Principle
|
Absolute and gauge pressure
|
Characteristic
|
Digital transmitter with piezoresistive sensor and diaphragm seal
Modular transmitter Long term stability Minimum oil volume process connection Enhanced safety via self diagnostic functions Secondary process barrier |
Supply Voltage
|
4...20 mA HART
10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy
|
0,075% + influence of diaphragm seal
|
Long Term Stability
|
0.05 % of URL/ year
0.07 % of URL/ 5 years 0.1 % of URL/ 10 years |
Process Temperature
|
-70°C...400°C
(-94°F...752°F) |
Ambient Temperature
|
-50°C...85°C
(-58°F...185°F) |
Measuring Cell
|
400 mbar...400 bar
(5.8 psi...6000 psi) relative/ absolute |
Smallest Calibratable Span
|
5 mbar (0.075 psi)
|
Vacuum Resistance
|
10 mbar (0.15 psi)
|
Max. Turn Down
|
100:1
|
Max. Overpressure Limit
|
1050 bar (15.750 psi)
|
Process Connection
|
Thread:
G1/2...G2, R1/2, MNPT1/2...MNPT2, NPT1/2...NPT1 Flange: DN25...DN100, ASME 1"...4", JIS 10K Diaphragm seal |
Process Connection Hygienic
|
Tri-Clamp
DIN11851 NEUMO Varivent SMS DRD Universal adapter |
Material Process Membrane
|
316L, AlloyC,
Tantal Rhodium> Gold PTFE |
Material Gasket
|
None, diaphragm welded
|
Fill Fluid
|
Silicone oil,
Inert oil, Vegetable oil, High temperature oil, Low temperature oil, |
Material Housing
|
Die-cast aluminum,
AISI 316L |
Communication
|
4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals
|
ATEX, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC
|
Safety Approvals
|
SIL
|
Design Approvals
|
EN10204-3.1
NACE MR0103 |
Hygienic Approvals
|
3A, EHEDG
|
Marine Approvals
|
GL/ ABS
|
Specialities
|
Diagnostic functions
TempC Membrane |
Successor
|
PMP71B
|
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.