{"product_id":"fluke-prv240fs-proving-unit-test-voltage-indicators-副本","title":"Fluke 1770 Series Three-Phase Power Quality Analyzers","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch3\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting.\u003c\/h3\u003e\n\u003cp\u003eFluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord\u003c\/p\u003e\n\u003cp\u003eWith the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eAutomatic measurement capture\u003c\/h3\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/2a69968b-a1c3-449b-bb50-b108002df4d2_original__size.jpg\" alt=\"Fluke 1770 Series Three-Phase Power Quality Analyzers Overview\" width=\"1500\" height=\"1000\" title=\"Fluke 1770 Series Three-Phase Power Quality Analyzers Overview\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"container-flex\"\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/d55e03f9-63af-4cef-886a-b108002d6a4b_original__size.jpg\" alt=\"Power Quality Logger\" width=\"1024\" height=\"683\" title=\"Power Quality Logger\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eUltimate measurement confidence\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003ePowerful analysis software with easy-to-create reports\u003c\/h3\u003e\n\u003cp\u003eFluke 1770 Series Power Quality Analyzers come standard with the powerful Fluke Energy Analyze Plus software, designed to eliminate the hassles found with other multi-purpose application software. Energy Analyze Plus helps you evaluate power quality data right out of the box and without extensive training.\u003c\/p\u003e\n\u003cp\u003eEnergy Analyze Plus makes downloading, analyzing, tracking, and reporting power quality and energy data easier than ever. Quickly compare results to historical values, benchmark against industry norms, compare measured data to local conditions, and create a more complete picture of what’s occurring across your facility, even as the data is still being collected. Energy Analyze Plus offers unified support for the Fluke 1730, 1740, and 1770 Series of Energy Loggers and Power Quality Analyzers.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“In-workshop” and “in-the-field” setup and download through PC application software\u003c\/li\u003e\n\u003cli\u003eSimple data downloads using USB memory stick, WiFi, LTE, wired Ethernet, or USB cable\u003c\/li\u003e\n\u003cli\u003eAnalyze every measured detail of energy consumption and power quality state-of-health with automated reporting\u003c\/li\u003e\n\u003cli\u003eOne-touch reporting creates standardized reports conforming to standards like EN 50160, IEEE 519, GOST 33073 IEC 61000-2-2, or export data in PQDIF or NeQual compatible format or CSV for use with third-party software\u003c\/li\u003e\n\u003cli\u003eAdvanced analysis allows the user to choose any available logged parameter and create a highly customized view of measurements for advanced data correlation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/b514b7d1-d305-411c-9919-b108002c85d6_original__size.jpg\" alt=\"Power Quality\" width=\"1500\" height=\"1000\" title=\"Power Quality\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"container-flex\"\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/9843d2d0-5238-4024-a3a3-b108002da915_original__size.jpg\" alt=\"Power Quality Logger Transient\" width=\"1035\" height=\"690\" title=\"Power Quality Logger Transient\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eHigh-speed voltage transient capture\u003c\/h3\u003e\n\u003cp\u003eTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFrom traditional industrial systems to renewable energy systems to electric vehicles, we’ve got you covered\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series was designed to be safe and easy to use in any measurement environ¬ment. The 1770 Series allows you to capture a full range of power quality variables as well as high-speed waveforms, high-speed transients, and higher frequency harmonics, all of which are instantly viewable on the large, high-resolution screen. With a best-in-class CAT IV 600 V \/ CAT III 1000 V overvoltage rating, these analyzers can be used at the service entrance or downstream, measuring AC and DC inputs, and harmonics measuring up to 30 kHz. With the 1770 Series you can be confident that you’ll capture the data you need to make better maintenance decisions no matter the task.\u003c\/p\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplications\u003c\/th\u003e\n\u003cth\u003e1773\u003c\/th\u003e\n\u003cth\u003e1775\u003c\/th\u003e\n\u003cth\u003e1777\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy surveys and load testing\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic surveys\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNuisance circuit breaker tripping\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric utility power quality surveys\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscovery of equipment failures caused by 8kV microsecond transients\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscovery of equipment failures caused by 8kV nanosecond transients\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/02865a6c-1d5e-47ae-ad1f-b108002d6a0f_original__size.jpg\" alt=\"Power Quality Logger\" width=\"1024\" height=\"683\" title=\"Power Quality Logger\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCompliant to international standards\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series offers the best-in-class accuracy you’ve come to expect from a Fluke Power Quality Analyzer in a future IEC 61000-4-30 Class A edition 3 compliant package. On top of that, the 1770 Series has been engineered to meet the future requirements of Class A edition, for conformance to EN 50160 and IEEE 519, so you’ll be prepared to tackle tomorrow’s measurement requirements, today.\u003c\/p\u003e\n\u003cdiv class=\"container-flex\"\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/5a1ef18c-2315-47ba-bd26-b108002df4ab_original__size.jpg\" alt=\"Fluke 1770 Series Three-Phase Power Quality Analyzers\" width=\"1500\" height=\"1000\" title=\"Fluke 1770 Series Three-Phase Power Quality Analyzers\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eWork where, when, and how you want\u003c\/h3\u003e\n\u003cp\u003eNo two days in the field are the same. You need a power quality analyzer that can go where you go and do what you need it to when you get there. With a full range of accessories and built-in features the Fluke 1770 Series makes it easier to get your job done. The slim ergonomic design and integrated hand strap make it easy to hold and the included hanging kit makes it easy to secure your analyzer inside a cabinet. The integrated internal power supply allows the unit to be powered directly from the measured circuit, while a 90-minute battery helps ensure you can still access and review data even when you aren’t connected to a live system.\u003c\/p\u003e\n\u003cp\u003eQuickly and easily transfer data to your PC using the USB C, USB A, Ethernet, Wi-Fi, cellular network support options, depending on your requirements. With an internal GPS module and an optional double insulated antenna extension cable, for amplifying GPS signals indoors, you can easily time sync your data for more accurate troubleshooting and analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eCalculate current harmonics limits\u003c\/h3\u003e\n\u003cp\u003eWhen downloading data from the Fluke 1770 Series Power Quality Analyzers the included Energy Analyze Plus software package can compare measured voltage and current harmonic statistical data to different standards, like EN 50160 or IEEE 519, to determine if they exceed compliance limits. This powerful predictive maintenance feature enables current harmonics to be observed before distortion appears in the voltage allowing you to prevent unexpected failures or non-compliance situations and increase system uptime. With the proliferation of inverter-based loads and power generation, keeping current harmonics in check is becoming increasingly critical to ensure reliable power quality and avoid system downtime.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/5942c313-daac-40e8-a659-b108002d6a1f_original__size.jpg\" alt=\"Fluke 1770 Series Three-Phase Power Quality Analyzers\" width=\"1024\" height=\"683\" title=\"Fluke 1770 Series Three-Phase Power Quality Analyzers\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"container-flex\"\u003e\n\u003cdiv\u003e\u003cimg class=\"img-responsive lazyloaded\" src=\"https:\/\/media.fluke.com\/fc3fa773-8ec9-4205-b604-b309015900e5_original__size.jpg\" width=\"599\" height=\"399\" title=\"Energy Loss Calculator\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eCalculate money lost to energy waste in terms of real dollars with the Energy Loss Calculator\u003c\/h3\u003e\n\u003cp\u003eThe Energy Loss Calculator (ELC) mode in the Fluke 1770 Series Power Quality Analyzers is designed to discover where energy losses exist in your electrical system using Fluke’s patented Unified Power calculation developed by the University of Valencia. In every electrical system, some energy is wasted and that energy is not delivered to the loads in your system to drive them. This waste comes from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransmission of effective power – Heat generated as power flows through cables\u003c\/li\u003e\n\u003cli\u003eReactive power – Does not drive the load but consumes energy\u003c\/li\u003e\n\u003cli\u003eUnbalance losses – Unbalanced loads contribute to wasted energy\u003c\/li\u003e\n\u003cli\u003eDistortion power – Non-linear loads create harmonics that consume power, but do not perform work\u003c\/li\u003e\n\u003cli\u003eNeutral losses – Neutral losses can be due to both unbalance and harmonics, leading to increased heat and requiring larger conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecial features \u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eNew Firmware Update: Energy Loss Calculator\u003c\/li\u003e\n\u003cli\u003eAutomatically measure power and power quality parameters\u003c\/li\u003e\n\u003cli\u003eAt-a-glance power quality health for faster troubleshooting\u003c\/li\u003e\n\u003cli\u003eEasily view V\/A\/Hz, power, dips, swells, and harmonics data\u003c\/li\u003e\n\u003cli\u003eCapture high-speed transients up to 8 kV\u003c\/li\u003e\n\u003cli\u003ePower directly from measurement circuit without a line cord\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003ch2\u003eModels: Fluke 1770 Series Three-Phase Power Quality Analyzers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1773\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5117269\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1773 Power Quality Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5117269\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 91766 7\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003ePackaging Includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1773 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1M USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cords (US, EU, UK, AUS, BRA)\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1773\/BASIC\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5272757\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1773\/Basic Power Quality Analyzer (No probes)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5272757\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 01850 7\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003ePackaging Includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1773 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1M USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cords (US, EU, UK, AUS, BRA)\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1775\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5117278\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1775 Power Quality Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5117278\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 91767 4\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003ePackaging Includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1775\/BASIC\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5272784\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1775\/Basic Power Quality Analyzer (No probes)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5272784\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 01853 8\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003ePackaging Includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clip\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1777\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5126630\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1777 Power Quality Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5126630\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 91901 2\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003ePackaging Includes24\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1777 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A  IN (2.0M) current probes\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clip\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eFLUKE-1777 HARDCASE rolling hard case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1777\/BASIC\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5272819\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1777\/Basic Power Quality Analyzer (No probes)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5272819\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 01856 9\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003ePackaging Includes\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1777 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clip\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eFLUKE-1777 HARDCASE rolling hard case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1777\/FPC\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5437565\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1777 Power Quality Analyzer Bundled with Premium Care 1-Year Standard Plan\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5437565\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePremium Care 1-Year Standard Plan\u003c\/li\u003e\n\u003cli\u003eFLUKE-1777 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clip\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFLUKE-1775\/FPC\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5335300\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1775 Power Quality Analyzer Bundled with Premium Care 1-Year Standard Plan\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5335300\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 7 54082 15531 7\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePremium Care 1-Year Standard Plan\u003c\/li\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 18 iFLEX 1500A 18 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFPC1S-FPQ170-1\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5326110\" class=\"model-desc\"\u003e\n\u003cp\u003ePremium Care 1-Year Standard Plan for Fluke 177X Series PQ Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5326110\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 03834 5\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cp\u003ePremium Care 1-Year Standard Plan\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFPC3S-FPQ170-1\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5326122\" class=\"model-desc\"\u003e\n\u003cp\u003ePremium Care 3-Year Standard Plan for Fluke 177X Series PQ Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5326122\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 03835 2\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cp\u003ePremium Care 3-Year Standard Plan\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFPC1G-FPQ170-1\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5326809\" class=\"model-desc\"\u003e\n\u003cp\u003ePremium Care 1-Year Gold Plan for Fluke 177X Series PQ Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5326809\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 03843 7\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cp\u003ePremium Care 1-Year Gold Plan\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFPC3G-FPQ170-1\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5326811\" class=\"model-desc\"\u003e\n\u003cp\u003ePremium Care 3-Year Gold Plan for Fluke 177X Series PQ Analyzer\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5326811\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 1 95112 03844 4\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cp\u003ePremium Care 3-Year Gold Plan\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion\"\u003e\n\u003ch1\u003e\n\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVoltage inputs\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e4 inputs, 3 phases and neutral referenced to PE (5 connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement category\u003c\/td\u003e\n\u003ctd\u003e1000 V CAT III \/ 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V rms \/ 1000 V dc (1700 Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage range\u003c\/td\u003e\n\u003ctd\u003eWye and single phase: variable (50 V – 1000 V)\u003cbr\u003eDelta: Variable (100 V – 1000 V)\u003cbr\u003eIEC 61000-4-30 Class A compliance for the nominal voltages (V\u003csub\u003edin\u003c\/sub\u003e) 100 V – 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 30 kHz for PQ measurements, excluding transients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e24-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling frequency\u003c\/td\u003e\n\u003ctd\u003e80 kS\/s at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScaling\u003c\/td\u003e\n\u003ctd\u003e1:1, variable for use of potential transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVoltage transients\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e±8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003e1775: 1 MS\/s\u003cbr\u003e1777: 1 MS\/s, 20 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger\u003c\/td\u003e\n\u003ctd\u003eAdjustable trigger level. Triggers on high-frequency components \u0026gt; 1.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003eCurrent inputs\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e4 inputs 3 phases and Neutral, range selected automatically to attached sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003ctd\u003e1 A to 1500 A with i17XX-FLEX1500 12\u003cbr\u003e1 A to 1500 A with i17XX-FLEX1500 18\u003cbr\u003e1 A to 1500 A with i17XX-FLEX1500 24\u003cbr\u003e3 A to 3000 A with i17XX-FLEX3000 24\u003cbr\u003e6 A to 6000 A with i17XX-FLEX6000 36\u003cbr\u003e40 mA to 40 A with clamp i40s-EL\u003cbr\u003e4 A to 400 A with clamp i400s-EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003e20 A to 2000 A with 80i-2010-EL clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 30 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e24-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSampling frequency\u003c\/td\u003e\n\u003ctd\u003e80 kS\/s at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eScaling\u003c\/td\u003e\n\u003ctd\u003e1:1, variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003eClamp: 50 mV \/ 500 mV rms; CF 2.8\u003cbr\u003eRogowski Coil: 15 mV \/ 150 mV rms at 50 Hz, 18 mV \/ 180 mV rms at 60 Hz; CF 4\u003cbr\u003eall at nominal probe range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e11 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eAux inputs\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWired connection with 17XX-AUX adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput range\u003c\/td\u003e\n\u003ctd\u003eDirect: 0 V dc to ± 10 V dc\u003cbr\u003e0 V to 1000 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003eDirect: 2.92 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale factor\u003c\/td\u003e\n\u003ctd\u003eFormat: mx + b (gain and offset) user configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed units\u003c\/td\u003e\n\u003ctd\u003eUser configurable (up to 8 characters, for example °C, psi, or m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eData acquisition voltage and current\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput mains frequency\u003c\/td\u003e\n\u003ctd\u003eDC, 50\/60 Hz  15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopologies\u003c\/td\u003e\n\u003ctd\u003e1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron\/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage\u003c\/td\u003e\n\u003ctd\u003eFluke 1773\/1775: 8 GB internal (expandable with microSD card)\u003cbr\u003eFluke 1777: 32 GB microSD card (installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory size\u003c\/td\u003e\n\u003ctd\u003eTypical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.\u003cbr\u003eThe number of possible logging sessions and logging period depends on user requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal time accuracy\u003c\/td\u003e\n\u003ctd\u003eInternal: 3 ppm (0.26 s per day, 8 s per month)\u003cbr\u003eNTP (internet time): Depending on internet latency, typical \u0026lt; 0.1 s absolute to UTC\u003cbr\u003eGPS: \u0026lt; 1 ms absolute to UTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTrend interval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured parameter\u003c\/td\u003e\n\u003ctd\u003eSee operator manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend interval\u003c\/td\u003e\n\u003ctd\u003eUser selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAveraging interval min\/max values\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)\u003cbr\u003eAux, Power: 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd\u003eTHD for voltage and current is calculated on 50 harmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\"\u003ePower quality measurements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMeasured parameter\u003c\/td\u003e\n\u003ctd\u003eSee operator manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003eh0 … h50\u003cbr\u003e% fund and RMS for voltage, current and power\u003cbr\u003ePhase angles for voltage and current up to h11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInterharmonics\u003c\/td\u003e\n\u003ctd\u003eih0… ih50\u003cbr\u003e% fund and RMS for voltage and current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSupraharmonics\u003c\/td\u003e\n\u003ctd\u003e2–9 kHz with 200 Hz bins\u003cbr\u003e9–30 khz with 2 kHz bins\u003cbr\u003eRMS for voltage and current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHarmonics measurement method\u003c\/td\u003e\n\u003ctd\u003eGrouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.\u003cbr\u003eMethod selected automatically based on configured PQ standard or user configurable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd\u003eCalculated on up to 50 harmonics (depends on selected PQ standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMains signaling\u003c\/td\u003e\n\u003ctd\u003e2 frequencies in the range from 110 Hz to 3000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEvents\u003c\/td\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eDip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003eInrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTriggered recordings\u003c\/td\u003e\n\u003ctd\u003eHalf cycle RMS of voltage and current for 10 s\u003cbr\u003eWaveform of voltage and current for 10\/12 cycles\u003cbr\u003eMains signaling: 200 ms RMS of mains signaling voltage up to 120 s\u003cbr\u003eTransients: Waveform of voltage\u003cbr\u003e(Fluke 1777: 1 MS\/s or 20 MS\/s, 500,000 pts, Fluke 1775: 1 MS\/s, 25,000 pts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandard compliance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eIEEE 1459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-7: Class 1\u003cbr\u003eIEEE 519 (short time and very short time harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-15 Class F1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower quality\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-30 Class A, IEC 62586 PQI-A-PI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower quality compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50160 + GOST + NEQUAL + NETCODE + FOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eInterfaces\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e1 Gbit\/s 1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB type A\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)\u003cbr\u003eAuxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)\u003cbr\u003eUSB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiFi\/BLE module\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e802.11 ac 2.4 GHz \/ 5 GHz, support for concurrent access point and client mode\u003cbr\u003eBluetooth 5.0\/BLE\u003cbr\u003eAntenna: Internal and external\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGPS\u003c\/td\u003e\n\u003ctd\u003eMCX connector to attach a GNSS antenna for GPS\/GLONASS\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003csup\u003e1\u003c\/sup\u003e Not in 177X\/BASIC versions\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e Requires 5m extension cable, Fluke p\/n 5263915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical measurement accuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eIntrinsic Accuracy at Reference Conditions\u003cbr\u003e% of Reading + % of Full Scale\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.1 % of nominal voltage\u003cbr\u003ein accordance with\u003cbr\u003eIEC 61000-4-30 Class A\u003csup\u003e1\u003c\/sup\u003e,\u003csup\u003e2\u003c\/sup\u003e\u003cbr\u003e  ±(0.04 % + 0.004 %)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage dips and swells\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.2 % of Vnom\u003csup\u003e1,2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage transients\u003c\/td\u003e\n\u003ctd\u003e±8 kVpk\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e±5 % +0.25 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage harmonics\/interharmonics\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003e0.1 % \/ 0.1 mV\u003c\/td\u003e\n\u003ctd\u003e≥1 % Vnom\u003csup\u003e1\u003c\/sup\u003e:  ±2.5 % of rdg.\u003cbr\u003e\u0026lt;1 % Vnom1:  ±0.025 Vnom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTHD on voltage\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003e0.1 % \/ 0.1 V\u003c\/td\u003e\n\u003ctd\u003e±(2.5 % + 0.5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage distortions 2-9 kHz\u003c\/td\u003e\n\u003ctd\u003eMax 100 V\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e±(2.5 % + 0.1 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage distortions 9-30 kHz\u003c\/td\u003e\n\u003ctd\u003eMax 100 V\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e±(2.5 % + 0.1 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eCurrent\u003cbr\u003e(Rogowski clamp mode)\u003c\/td\u003e\n\u003ctd\u003eWith iFlex 1500 A,\u003cbr\u003ei17XX-FLEX1500 18\u003c\/td\u003e\n\u003ctd\u003e150 A\u003cbr\u003e1500 A\u003c\/td\u003e\n\u003ctd\u003e0.01 %\u003cbr\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.02 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith iFlex 3000 A,\u003cbr\u003ei17XX-FLEX3000 24\u003c\/td\u003e\n\u003ctd\u003e300 A\u003cbr\u003e3000 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A\u003cbr\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(1 % + 0.03 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith iFlex 6000 A,\u003cbr\u003ei17XX-FLEX6000 36\u003c\/td\u003e\n\u003ctd\u003e600 A\u003cbr\u003e6000 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003cbr\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±(1.5 % + 0.03 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith AC clamp 40 A,\u003cbr\u003ei40s-EL\u003c\/td\u003e\n\u003ctd\u003e4 A\u003cbr\u003e40 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e±(0.7 % + 0.02 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith AC clamp 400 A,\u003cbr\u003ei400s-EL\u003c\/td\u003e\n\u003ctd\u003e40 A\u003cbr\u003e400 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A\u003cbr\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(2 % + 0.2 %)\u003cbr\u003e ±(0.7 % + 0.1 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWith AC\/DC clamp\u003cbr\u003e2000 A, 80i-2010s-EL\u003c\/td\u003e\n\u003ctd\u003e200 A\u003cbr\u003e2000 A\u003c\/td\u003e\n\u003ctd\u003e0.01 A\u003cbr\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(0.8 % + 0.2 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCurrent min\/max\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003edefined by accessory\u003c\/td\u003e\n\u003ctd\u003ex2 of intrinsic accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCurrent harmonics\/interharmonics\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003e0.1 % \/ 0.01 A\u003c\/td\u003e\n\u003ctd\u003e≥3 % Inom:  ±2.5 % of rdg.4\u003cbr\u003e\u0026lt;3 % Inom:  ±0.15 % of Inom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTHD on current\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e±(2.5 % + 0.5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e42.5 Hz … 69 Hz\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage unbalance\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e±0.15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCurrent unbalance\u003c\/td\u003e\n\u003ctd\u003e100 %\u003c\/td\u003e\n\u003ctd\u003e0.1 %\u003c\/td\u003e\n\u003ctd\u003e±0.15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFlicker Pinst, Pst, Plt\u003c\/td\u003e\n\u003ctd\u003e0 to 20\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMains signaling voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 3 kHz\u003cbr\u003e0-15 % of Vnom\u003c\/td\u003e\n\u003ctd\u003e0.1 V \/ 0.1 %\u003c\/td\u003e\n\u003ctd\u003e1-3 % Vnom: ±0.15 % of Vnom\u003cbr\u003e3-15 % Vnom: ±5 % of rdg.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAUX input\u003c\/td\u003e\n\u003ctd\u003e±10 V\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e±(0.2 % + 0.05 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003csup\u003e1\u003c\/sup\u003e Nominal voltage in the range of 100 V to 690 V. Also known as Udin.\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e 0 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x3\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Only for calibration laboratories\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003e With iFlex 1500A, I17XX-FLEX1500 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePower\/Energy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDirect Input\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth\u003eClamp i40S-EL\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePower range W, VA, var\u003c\/td\u003e\n\u003ctd\u003eClamp: 50 mV \/ 500 mV\u003cbr\u003eRogowski: 15 mV \/ 150 mV\u003c\/td\u003e\n\u003ctd\u003e4 A \/ 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp: 50 W \/ 500 W\u003cbr\u003eRogowski: 15 W \/ 150 W\u003c\/td\u003e\n\u003ctd\u003e4k W \/ 40 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution W, VA, var\u003c\/td\u003e\n\u003ctd\u003e0.1 W\u003c\/td\u003e\n\u003ctd\u003e1 W \/ 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase (voltage to current)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±0.2\u003csup\u003e°\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1\u003csup\u003e°\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eiFlex 1500A, I17XX-FLEX1500 18\u003c\/th\u003e\n\u003cth\u003eiFlex 3000A, I17XX-FLEX3000\u003c\/th\u003e\n\u003cth\u003eiFlex 6000A, I17XX-FLEX6000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePower range W, VA, var\u003c\/td\u003e\n\u003ctd\u003e150 A \/ 1500 A\u003c\/td\u003e\n\u003ctd\u003e300 A \/ 3000 A\u003c\/td\u003e\n\u003ctd\u003e600 A \/ 6000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150 kW \/ 1.5 MW\u003c\/td\u003e\n\u003ctd\u003e300 kW \/ 3 MW\u003c\/td\u003e\n\u003ctd\u003e600 kW \/ 6 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resolution W, VA, var\u003c\/td\u003e\n\u003ctd\u003e0.1 kW \/ 1kW\u003c\/td\u003e\n\u003ctd\u003e1 kW \/10 kW\u003c\/td\u003e\n\u003ctd\u003e1 kW \/ 10k W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003eI17XX-FLEX1500 18\u003c\/th\u003e\n\u003cth\u003eI17XX-FLEX3000\u003c\/th\u003e\n\u003cth\u003eI17XX-FLEX6000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eActive power P\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ePF ≥ 0.99\u003c\/td\u003e\n\u003ctd\u003e150 A \/ 1500 A\u003c\/td\u003e\n\u003ctd\u003e300 A \/ 3000 A\u003c\/td\u003e\n\u003ctd\u003e600\/6000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.2 % + 0.005 %\u003c\/td\u003e\n\u003ctd\u003e1.2 % + 0.0075 %\u003c\/td\u003e\n\u003ctd\u003e1.7 % + 0.0075 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive energy E\u003csub\u003ea\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.1 ≤ PF \u0026lt; 0.99\u003c\/td\u003e\n\u003ctd\u003e(1.2+√(1-PF\u003csup\u003e2\u003c\/sup\u003e)\/(2 PF)) % + 0.005 %\u003c\/td\u003e\n\u003ctd\u003e(1.2+√(1-PF\u003csup\u003e2\u003c\/sup\u003e)\/(2 PF)) % + 0.0075 %\u003c\/td\u003e\n\u003ctd\u003e(1.7+√(1-PF\u003csup\u003e2\u003c\/sup\u003e)\/(2 PF)) % + 0.0075 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent power S\u003cbr\u003eApparent energy E\u003csub\u003eap\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd\u003e1.2 % + 0.005 %\u003c\/td\u003e\n\u003ctd\u003e1.2 % + 0.0075 %\u003c\/td\u003e\n\u003ctd\u003e1.7 % + 0.0075 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReactive power Q\u003cbr\u003eReactive energy E\u003csub\u003er\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.5 % of measured apparent power\/energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional uncertainty\u003cbr\u003e(% of power high range)\u003c\/td\u003e\n\u003ctd\u003eVP-N \u0026gt; 250 V\u003c\/td\u003e\n\u003ctd\u003e0.02 %\u003c\/td\u003e\n\u003ctd\u003e0.02 %\u003c\/td\u003e\n\u003ctd\u003e0.02 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase (voltage to current)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e0.28\u003csup\u003e°\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.28\u003csup\u003e°\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.28\u003csup\u003e°\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp\u003e\u003csup\u003e1\u003c\/sup\u003e Nominal voltage in the range of 100 V to 690 V. Also known as Udin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReference Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnvironmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u0026lt;65 %\u003c\/p\u003e\n\u003cp\u003eInput conditions: Cos Φ\/PF=1, Sinusoidal signal f=50\/60 Hz, power supply 120 V\/230 V ±10 %.\u003c\/p\u003e\n\u003cp\u003eCurrent and power specifications: Input voltage \u0026gt;100V\u003c\/p\u003e\n\u003cp\u003eInput current \u0026gt; 10 % of current range\u003c\/p\u003e\n\u003cp\u003ePrimary conductor of clamps or Rogowski coil in center position\u003c\/p\u003e\n\u003cp\u003eTemperature coefficient: Add 0.1 x specified accuracy for each degree \u003csup\u003e°\u003c\/sup\u003eC above 28 \u003csup\u003e°\u003c\/sup\u003eC or below 18 \u003csup\u003e°\u003c\/sup\u003eC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eKey features\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eAnalyzer: 2 years (battery not included)\u003cbr\u003eAccessories: 1 year (including battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L X W X HD)\u003c\/td\u003e\n\u003ctd\u003e28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg (4.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti-theft protection\u003c\/td\u003e\n\u003ctd\u003eSlot to support Kensington lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironmental specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-10 \u003csup\u003e°\u003c\/sup\u003eC to 50 \u003csup\u003e°\u003c\/sup\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-20 \u003csup\u003e°\u003c\/sup\u003eC to 60 \u003csup\u003e°\u003c\/sup\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003eIEC 60721-3-3: 3K5, modified:\u003cbr\u003e-10 \u003csup\u003e°\u003c\/sup\u003eC to 30 \u003csup\u003e°\u003c\/sup\u003eC: ≤95 %, no condensation or ice\u003cbr\u003e35 \u003csup\u003e°\u003c\/sup\u003eC: 70 %\u003cbr\u003e40 \u003csup\u003e°\u003c\/sup\u003eC: 55 %\u003cbr\u003e50 \u003csup\u003e°\u003c\/sup\u003eC: 35 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eIEC 60721-3-3 \/ 3M2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower supply\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage range\u003c\/td\u003e\n\u003ctd\u003e100 V – 600 V -15 % \/ +10 % (85 V … 660 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (42.5 Hz … 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS\u003c\/td\u003e\n\u003ctd\u003eLi-Ion battery BP1770 with extended temperature range, customer replaceable\u003cbr\u003eOn-battery runtime: 1.5 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSafety\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Category IV 600 V\u003cbr\u003eWith Mains Adapter MA-C8: Overvoltage Category II 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-030: CAT IV 600 V, CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitudes 2000 m to 4000 m\u003c\/td\u003e\n\u003ctd\u003eDerate to:\u003cbr\u003ePower Supply: Category IV 300 V\u003cbr\u003eWith MA-C8 Adapter: Category II 150 V\u003cbr\u003eMeasurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"clickability\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":56200445395266,"sku":null,"price":5000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/Fluke_1770_Series_Three-Phase_Power_Quality_Analyzers.png?v=1789705202","url":"https:\/\/antletstech.com\/ru\/products\/fluke-prv240fs-proving-unit-test-voltage-indicators-%e5%89%af%e6%9c%ac","provider":"ANTLETS","version":"1.0","type":"link"}