{"product_id":"endress-hauser-cls21e-memosens-2-0-contacting-conductivity-sensor-副本-1","title":"Endress+Hauser Analog conductivity sensor Condumax CLS21D","description":"\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"eh-upid-header--description eh-p-t-2 eh-font-metrics--18-24\"\u003e\u003cstrong\u003eConductive conductivity sensor for medium to high measuring ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eApplication\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp class=\"eh-p-v\"\u003eCondumax CLS21 is a robust conductivity sensor for all process and environmental applications. It provides you with precise and reliable measuring values for an optimum process and product quality monitoring. Better still, the sensor features high chemical, thermal and mechanical stability and high durability.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"eh-p-b-lg\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"eh-rich-content-content\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eCondumax CLS21 measures conductivity in all process and environmental applications, such as:\u003c\/p\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003ePotable water treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eDesalination plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eIndustrial water treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eRiver\/lake monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003ePhase separation in medium conductivities (e.g. milk\/water)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"eh-generic--text\"\u003eWith its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\n\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h1\u003e\n\u003cul class=\"eh-list-01 eh-generic--list\"\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eReliable and accurate measuring values at medium to high conductivities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eRobust design for long durability and low maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eHigh chemical, thermal and mechanical stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"eh-list--item\"\u003e\n\u003cp class=\"eh-generic--text\"\u003eQuality certificate stating the individual cell constant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003ctable height=\"1067\" style=\"width: 100%; height: 972.423px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eitem\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003evalue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eGrade\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eIndustrial\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eWarranty\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003e1 Year\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eCustomized support\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eOEM\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003ePlace of Origin\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eGermany\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eBrand Name\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eEndress+Hauser\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eModel Number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003eCLS21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eMode\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eConductivity Sensor \u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 19.5938px;\"\u003e\n\u003cdiv\u003eMeasuring Principle\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 19.5938px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eConductive\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 97.9688px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 97.9688px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eApplication\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 97.9688px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eWater, waste water, process, media separation, industrial water.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 78.375px;\"\u003e\n\u003cdiv\u003eCharacteristic \/ Application\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 78.375px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003e2-electrode system for application in the middle application range.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.75px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 58.75px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMeasuring range\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 58.75px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003ek=1: 10 µS\/cm to 20 mS\/cm\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMeasuring principle\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eConductive conductivity cell with graphite electrodes for applications in the middle range.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eDesign\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003e2-electrode conductivity cell with parallel arranged electrodes\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eMaterial\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eCell shaft: PES\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eElectrodes: graphite\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 78.375px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 78.375px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eDimension\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 78.375px;\"\u003e\n\u003cspan\u003eDiameter: 24 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(0.936 inch)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLength: 61 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2.37 inch)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 117.547px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 117.547px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eProcess temperature\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 117.547px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003emax. 135°C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(max. 275°F)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 39.1875px;\"\u003e\n\u003cdiv\u003eProcess pressure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 39.1875px;\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003emax. 16 bar at 20°С\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e(max. 232psi at 68°F)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 35.5938px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eTemperature sensor\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 35.5938px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eOptional with integrated Pt100 or PTC temperature sensor.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.75px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 58.75px;\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eEx certification\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 58.75px;\"\u003e\n\u003cdiv\u003e\u003cspan\u003eATEX\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 58.7812px;\"\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eConnection\u003c\/p\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 58.7812px;\"\u003e\n\u003cspan\u003eProcess connection: DN25, DN40, G1, NPT 1\"\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSensor connection: Inductive, digital connection head with Memosens 2.0 technology\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5938px;\"\u003e\n\u003ctd style=\"width: 37.177%; height: 35.5938px;\"\u003e\n\u003cp class=\"eh-headline--04 eh-font-sans eh-p-r-lg--large eh-p-r-lg--medium\"\u003eIngress protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 62.462%; height: 35.5938px;\"\u003e\n\u003cp\u003e\u003cspan\u003eIP65 (connector)IP67 (fixed cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":54917202936130,"sku":"107593955310","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/Endress_Hauser_Analog_conductivity_sensor_Condumax_CLS21.png?v=1782378782","url":"https:\/\/antletstech.com\/ru\/products\/endress-hauser-cls21e-memosens-2-0-contacting-conductivity-sensor-%e5%89%af%e6%9c%ac-1","provider":"ANTLETS","version":"1.0","type":"link"}