{"product_id":"electromagnetic-flowmeter-hygienicmaster-feh500","title":"ABB Electromagnetic flowmeter HygienicMaster FEH500","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eThe HygienicMaster FEH500 enhanced version is designed specifically for the food \u0026amp; beverage, pharmaceutical  and biotechnical industries. Manufactured from FDA approved materials and certified in accordance with 3-A.\u003c\/p\u003e\n\u003cp\u003eAvailable as integral mount design or remote mount design system.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe stainless steel exterior, the variable process connection, the advanced signal processing and the state-of-the-art data storage provide a complete and cost effective flow solution.\u003cbr\u003eHygienicMaster FEH500 is a versatile, reasonably priced, most accurate flow meter tailored for all process industry applications. A flowmeter with extended functionality and options, short delivery and a simple and clearly understandable documentation.   \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntuitive and simple configuration\u003cbr\u003e– Through glass configuration eliminating the need to remove the cover and reducing commissioning time\u003cbr\u003e– Soft key based functionality\u003cbr\u003e– \"Easy Set-up\" function  \u003c\/li\u003e\n\u003cli\u003eState-of-the-art memory technology\u003cbr\u003e– Data storage enables transmitter exchange without the need for reconfiguration\u003c\/li\u003e\n\u003cli\u003eDiagnostics for real-life-situations \u003cbr\u003e– Status messages in accordance with NAMUR\u003cbr\u003e– Help texts in LCD display\u003c\/li\u003e\n\u003cli\u003eExtended diagnostic and monitoring functions\u003cbr\u003e– Electrode coating detection\u003cbr\u003e– Gas bubble detection\u003cbr\u003e– Conductivity and sensor temperature monitoring\u003cbr\u003e– Grounding verification \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eScanMaster in situ verification software option\u003cbr\u003e– Allows the customer to perform in situ verification of the flowmeter and the plant \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy for Hygienic Processes\u003c\/strong\u003e\u003cbr\u003eProvides precise and stable flow measurement for demanding food, beverage and pharmaceutical applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Process Reliability\u003c\/strong\u003e\u003cbr\u003eAdvanced diagnostics help identify process conditions and reduce unexpected downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Commissioning and Maintenance\u003c\/strong\u003e\u003cbr\u003eSensor data storage and self-configuration simplify installation and transmitter replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Cleaning Effort\u003c\/strong\u003e\u003cbr\u003eHygienic design supports CIP\/SIP cleaning procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Process Integration\u003c\/strong\u003e\u003cbr\u003eMultiple hygienic connection options allow easy installation into different process systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Batch Processing\u003c\/strong\u003e\u003cbr\u003eIntegrated batch functions support filling and dosing applications.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eitem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003evalue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eaccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3% of rate (Optional ±0.2% of rate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003etype\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHygienic Electromagnetic Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ebrand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emodel number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFEH500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Inductive Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConductive Liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eflow measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eVolume Flow Measurement of Hygienic Liquid Media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasuring principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFaraday's Law of Electromagnetic Induction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003enominal diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDN 1 to DN 100 (1\/25 to 4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eoutput signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA; Pulse\/Frequency Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecommunication protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHART; PROFIBUS PA; FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eThrough-The-Glass (TTG) Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003elocal operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration without Opening the Housing via Soft Keys and Easy Set-up Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eelectronics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Modular Transmitter with Sensor Data Storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003etransmitter design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact Mount Design or Remote Mount Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ediagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode Coating Detection, Gas Bubble Detection, Conductivity Monitoring, Sensor Temperature Monitoring, Grounding Verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ebatch function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePreset Counter, Overrun Correction, External Start\/Stop and Batch End Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003everification function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eScanMaster In-Situ Verification Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eprocess connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTri-Clamp, Weld Stubs, Threaded Pipe Connection, Flange and Hygienic Process Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eliner material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePFA (Vacuum Tight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eelectrode materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003efluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 150 °C (302 °F) for CIP\/SIP Cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epressure rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eprotection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 \/ IP68 (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3-A Sanitary Standard; FDA Approved Materials; EHEDG (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ehousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent (Compact or Remote Version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003efeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh Accuracy, Hygienic Design, Advanced Diagnostics, Batch Function, TTG Operation and Data Storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eapplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFood \u0026amp; Beverage, Pharmaceutical, Biotechnology and Hygienic Process Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56221374185794,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Electromagnetic_flowmeter_HygienicMaster_FEH500.png?v=1789983867","url":"https:\/\/antletstech.com\/ru\/products\/electromagnetic-flowmeter-hygienicmaster-feh500","provider":"ANTLETS","version":"1.0","type":"link"}