{"product_id":"abb-thermal-mass-flowmeter-sensymaster-fmt450","title":"ABB Thermal mass flowmeter SensyMaster FMT450","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(11, 72, 162);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eThe ABB SensyMaster FMT450 is an advanced thermal mass flowmeter designed for precise and dynamic direct mass flow measurement of gases and gas mixtures in industrial applications. Based on the hot-film anemometer measuring principle, it provides direct gas mass flow measurement under known gas composition conditions.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding gas measurement applications, the FMT450 combines high-grade thermal sensor elements, intelligent digital electronics, and flexible application configuration. Its advanced features include optional process gas calibration, extended measuring range, high-temperature measurement capability, and integrated diagnostic functions.\u003c\/p\u003e\n\u003cp\u003eWith the ApplicationSelector function, users can configure up to eight different applications, including selectable gas types and pipe inner diameters. The instrument also supports optional FillMass filling application software and VeriMass sensor diagnostics.\u003c\/p\u003e\n\u003cp\u003ePrecise and dynamic direct mass flow measurement of gases for industrial standard applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-grade thermal sensor elements\u003cbr\u003e– superior long-term stability\u003cbr\u003e– effective sensor element protection frame with flow conditioning properties\u003c\/li\u003e\n\u003cli\u003eSmartSensor solution\u003cbr\u003e– Meter intelligence located at the sensor\u003cbr\u003e– all digital solution\u003cbr\u003e– reduced wiring costs with industry standard connection cables\u003cbr\u003e– long cable distances are possible\u003c\/li\u003e\n\u003cli\u003eSensorApplicationMemory\u003cbr\u003e– Plug and play electronics replacement\u003cbr\u003e– Redundant data storage for maximum data security\u003c\/li\u003e\n\u003cli\u003eABB common electronic concept\u003cbr\u003e– Through-the-glass operation\u003cbr\u003e– Modular I\/O Concept\u003cbr\u003e– Multiple 32-bit processor structure\u003cbr\u003e– full digital heating circuit control\u003cbr\u003e– dynamic temperature compensation\u003c\/li\u003e\n\u003cli\u003eApplicationSelector\u003cbr\u003e– Adaption of the characteristic application parameters on site\u003cbr\u003e– choice between up to two applications (FMT430)\u003cbr\u003e– choice between up to eight applications (FMT450)\u003cbr\u003e– setup new applications without the need for recalibration (FMT450)\u003c\/li\u003e\n\u003cli\u003eVeriMass onboard verification and diagnostics\u003cbr\u003e– Fingerprint based SensorCheck to verify the integrity of the thermal sensor elements\u003cbr\u003e– continuous health check of the meter\u003cbr\u003e– parameter plausibility check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(12, 74, 167);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Accuracy Gas Measurement:\u003c\/strong\u003e Provides air measurement accuracy of ±0.6% of measured value plus ±0.05% of QmaxDN under reference conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Mass Flow Measurement:\u003c\/strong\u003e Thermal measurement technology enables direct gas mass flow measurement without additional pressure and temperature compensation when the gas composition is known and constant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible ApplicationSelector:\u003c\/strong\u003e Supports up to eight applications, including up to four freely configurable applications with selectable gas types and pipe inner diameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Gas Calibration:\u003c\/strong\u003e Optional process gas calibration is available for specific gases and gas mixtures to support demanding measurement applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Temperature Capability:\u003c\/strong\u003e Optional high-temperature sensor design supports measuring medium temperatures up to 300 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Measuring Range:\u003c\/strong\u003e Optional extended measuring range is available depending on the gas type and application requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Communication and I\/O:\u003c\/strong\u003e Standard HART communication and optional Modbus RTU or PROFIBUS DP interfaces, with additional inputs and outputs available through plug-in cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Internal device monitoring and optional VeriMass SensorCheck help verify sensor element integrity and monitor instrument condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Available in integral and remote mounting designs, with different sensor connections and pipe component configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(10, 75, 174);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAir: ±0.6% of measured value ±0.05% of QmaxDN.\u003cbr\u003eOther gases with optional process gas calibration: ±1.6% of measured value ±0.1% of QmaxDN.\u003cbr\u003eAccuracy specifications apply under the reference conditions and within the specified standard measuring range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eThermal Mass Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eBrand Name\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eModel Number\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSensyMaster FMT450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eMeasurement Type\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDirect Gas Mass Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eMeasurement Media\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAir, nitrogen, oxygen, methane, carbon dioxide, hydrogen, natural gas, biogas, propane, argon, ammonia, helium, ethane, ethylene, butane, and other gases subject to gas composition and application requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eLevel Measurement\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot Applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4–20 mA active or passive current output; two passive digital outputs configurable as pulse, frequency, or switch outputs. Additional analog and digital outputs are available through optional plug-in cards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Protocols\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHART 7.1 standard; optional Modbus RTU and PROFIBUS DP via plug-in cards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptional integrated LCD display with push buttons and through-the-glass operation; no-display configuration also available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Technology\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLCD indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eLocal Operation\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMenu-guided parameterization using four buttons through the front glass, with Easy Setup function for commissioning when the optional LCD indicator is installed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eElectronics\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eABB digital electronic platform with SmartSensor technology, SensorApplicationMemory, dynamic temperature compensation, and modular I\/O concept.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eTerminal Block\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower supply terminals L\/N for AC or 1+\/2− for DC; current output terminals Uco\/32 or 31\/32; digital output terminals 41\/42 and 51\/52; optional plug-in card terminals V1\/V2 and V3\/V4.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eTurndown Ratio\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMeasuring range dynamics up to 1:100, depending on application and configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eSafety Certification\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eATEX \/ IECEx and cFMus explosion protection options. SIL 2 certification available as an ordering option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegral or remote mounting design.\u003cbr\u003eSingle-compartment or dual-compartment transmitter housing options.\u003cbr\u003eApplicationSelector for up to 8 applications, including up to 4 freely configurable applications.\u003cbr\u003eOptional process gas calibration and extended measuring range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eFeatures\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHigh-grade thermal sensor elements, SmartSensor technology, SensorApplicationMemory, ApplicationSelector, dynamic temperature compensation, and internal device diagnostics.\u003cbr\u003eOptional VeriMass SensorCheck function and FillMass filling application software.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eApplications\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGas flow measurement in chemical and process industries, compressed air balancing, gas burner control, digester gas measurement, sewage treatment plant aeration, gas measurement in air separators, and hydrogen measurement in industrial processes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFlange DN 25 according to EN 1092-1, PN 40; male thread according to DIN 11851; NPT 1 in male-thread compression fitting, PN 20. Different pipe component designs are available depending on installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eElectrical Connection\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eM20 × 1.5 or 1\/2 in NPT cable gland options. Remote mounting design supports a maximum signal cable length of 100 m (328 ft).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eWetted Materials\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStainless steel sensor and ceramic sensor element. Sensor connection gasket materials include Viton, Kalrez, EPDM, FKM, and HNBR, depending on the selected design and application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCast aluminum transmitter housing with painted RAL 9002 finish. Single-compartment and dual-compartment configurations available. Selected remote sensor housing configurations are also available in stainless steel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68240337404226,"sku":null,"price":9000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Thermal_mass_flowmeter_SensyMaster_FMT450.png?v=1795492495","url":"https:\/\/antletstech.com\/ru\/products\/abb-thermal-mass-flowmeter-sensymaster-fmt450","provider":"ANTLETS","version":"1.0","type":"link"}