{"product_id":"abb-swirl-flowmeter-swirlmaster-fss450","title":"ABB Swirl flowmeter SwirlMaster FSS450","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(14, 74, 164);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eThe ABB SwirlMaster FSS450 is an intelligent swirl flowmeter designed for highly accurate measurement of gases, liquids, and steam over a wide range of temperatures. It is particularly suitable for low-viscosity liquids, demineralized water, and direct, cost-effective steam mass flow measurement.\u003c\/p\u003e\n\u003cp\u003eAs an advanced version of the SwirlMaster series, the FSS450 features an integrated digital output, external analog input, and flow computer functionality. It supports mass flow and energy flow calculations in many applications without requiring a separate flow computer.\u003c\/p\u003e\n\u003cp\u003eThe FSS450 is available with an integral or remote transmitter. For remote mounting, the sensor and transmitter can be connected using a signal cable up to 30 m (98 ft) long.\u003c\/p\u003e\n\u003cp\u003eAvailable communication options include 4–20 mA \/ HART 7, Modbus RTU, and Ethernet-APL. Modbus TCP and PROFINET are available via Ethernet-APL, depending on the device configuration.\u003c\/p\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(14, 78, 175);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Flow Computer Functionality:\u003c\/strong\u003e Supports gas standard volume and mass flow, vapor mass flow, and direct steam and water energy calculations, reducing the need for separate flow calculation equipment in many applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mass and Energy Measurement:\u003c\/strong\u003e Supports steam and water energy measurement and can use external pressure, temperature, or density signals for additional measurement and compensation functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Sensor Connectivity:\u003c\/strong\u003e The 4–20 mA analog input allows connection of external pressure transmitters, temperature transmitters, gas analyzers, or density measurement devices, depending on the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Measurement Accuracy:\u003c\/strong\u003e Provides flow measurement accuracy of ±0.50% of rate, according to the supplied general specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Digital Output:\u003c\/strong\u003e The digital output is standard and can be configured for pulse, frequency, or alarm output. Availability depends on the communication configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Communication Options:\u003c\/strong\u003e Offers HART 7, Modbus RTU, and Ethernet-APL communication options, with protocol availability depending on the selected configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation and Operation:\u003c\/strong\u003e Requires short straight pipe lengths and provides Easy Set-up, a clear-text display, and configuration through the front glass with the cover closed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e Available in integral or remote transmitter designs, with a maximum remote signal cable length of 30 m (98 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Safety:\u003c\/strong\u003e SIL 2 certification and explosion protection approvals are available depending on the selected device configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(17, 85, 187);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.50% of Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent Swirl Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFSS450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Volume Flow, Liquid Mass Flow, Gas Actual Volume Flow, Gas Standard Volume Flow, Gas Mass Flow, Steam Volume Flow, Steam\/Water Mass Flow, Steam\/Water Energy Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquids, Gases, and Steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot Applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA; Standard Digital Output Configurable as Pulse, Frequency, or Alarm Output, Depending on Communication Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART 7, Modbus RTU, Ethernet-APL; Modbus TCP and PROFINET via Ethernet-APL, Depending on Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD Indicator with Four Operating Buttons; Optional Smart HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy Set-up; Four Operating Buttons; Optional Through-the-Glass (TTG) Operation; Optional Bluetooth Configuration with Smart HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectronics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Transmitter Electronics with Integrated Flow Computer Functionality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 2 According to IEC 61508; Explosion Protection Approvals Include ATEX, IECEx, cFMus, and NEPSI, Depending on Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral or Remote Transmitter; Standard Digital Output; 4–20 mA Analog Input; Optional Smart HMI; Remote Signal Cable up to 30 m (98 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Flow Computer Functionality; External Analog Input; Gas Standard Volume and Mass Flow Calculation; Vapor Mass Flow Calculation; Steam\/Water Energy Measurement; Configurable Digital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid, Gas, and Steam Flow Measurement; Gas Standard Volume and Mass Flow; Steam\/Water Mass Flow and Energy Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange Design; DN15 to DN400 (1\/2 to 16 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel; Optional Hastelloy C; Gaskets: PTFE, Optional Kalrez or Graphite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmitter Housing: Die-Cast Aluminum or Stainless Steel, Depending on Order Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68234183737666,"sku":null,"price":7000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Swirl_flowmeter_SwirlMaster_FSS450_0.png?v=1794909373","url":"https:\/\/antletstech.com\/ru\/products\/abb-swirl-flowmeter-swirlmaster-fss450","provider":"ANTLETS","version":"1.0","type":"link"}