{"product_id":"fluke-52-ii-dual-probe-digital-thermometer-副本","title":"Fluke 7526A Precision Process Calibrator","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003eProduct overview: 7526A Precision Process Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch2\u003eA “best fit” for your process calibration requirements\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e“Doing more with less” is a requirement every process manufacturer faces today. To maintain product quality, reduce waste, improve efficiency and conform to regulatory standards, instruments that measure process variables such as temperature and pressure must be calibrated at regular intervals. Selecting the right calibrator for the job, however, can be tricky—especially when attempting to balance precision and versatility with cost. Less expensive than high-end multi-product calibrators, yet more precise and versatile than handheld field calibrators, the 7526A is a “best fit” for instrument shops that value precision, versatility and economy.\u003c\/p\u003e\n\u003ch2\u003eIntuitive user interface\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003eThe user interface includes cursor controls, function keys and a ten-key keypad, making it easy to navigate through intuitive menus; store and recall up to nine setpoints for each input\/output parameter; enter RTD or SPRT coefficients; and easily change display units with a key press. With two LCD displays, you can easily view both source and measurement results simultaneously.\u003c\/p\u003e\n\u003ch2\u003eIncrease efficiency through automation\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003eFor increased efficiency and calibration throughput, or to operate an automated test system (ATE), combine the 7526A with MET\/CAL® Plus Calibration Management Software. MET\/CAL Plus is a powerful application for creating, editing and testing calibration procedures and collecting and reporting results on a wide variety of instruments. It includes MET\/CAL® software– the industry leading software for automated calibration, and MET\/TEAM™ Express–a dedicated system to manage your test and measurement assets. Or choose MET\/TEAM™ standard edition for fully-featured enterprise calibration asset management, with optional modules for on-site calibration, commerce management, and customer web portal. The 7526A standard computer interface includes RS-232 and GPIB (IEEE-488). A USB-to-serial adapter cable is also included with the calibrator as standard.\u003c\/p\u003e\n\u003ch2\u003eDon’t forget the sensor\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003eCalibrating the electronics portion of a temperature transmitter is only a part of a complete calibration. You also need to calibrate the temperature sensor itself, whether an RTD or thermocouple. Ignoring the sensor can be a mistake, because temperature sensors are responsible for more than 75% of the output errors in temperature transmitters. You can calibrate the temperature sensor individually, or calibrate both the sensor and the transmitter as a system using a dry-block calibrator such as the Fluke Calibration 914X Series Field Metrology Wells. The Field Metrology Wells were designed specifically with process calibration in mind—optimizing speed to temperature, portability, stability and accuracy. The 7526A and a 914X dry-block calibrator make a perfect combination for calibrating just about any temperature transmitter.\u003c\/p\u003e\n\u003ch2\u003eSource as well as measure pressure\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003eThe P5500 series of comparison test pumps can be used with the 7526A and Fluke 700P and 750P series pressure modules to generate or control test pressures. The unique test port configuration allows for easy, tool-free connections of a wide variety of connection sizes and types, including NPT, BSP, and metric threads. The P5510 includes a built-in hand pump to generate vacuum or positive pressure up to 300 psi (2 MPa). The P5513 allows for precise control of pneumatic pressures up to 3000 psi (20 MPa). An external pressure supply is required. The P5514 allows for generation of hydraulic pressures up to 10 000 psi (70 MPa). The P5515 includes a built-in priming pump and screw pump that allows for pressure generation up to 20 000 psi (140 MPa). Both the P5514 and P5515 can be used with oil or water. Special versions are available with ethylene propylene seals for use with more aggressive fluids.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecial features \u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile, precise benchtop tool to source and measure DC voltage, current, resistance, RTDs and thermocouples.\u003c\/li\u003e\n\u003cli\u003eComprehensive calibration solution for temperature and pressure process instrumentation like RTD and thermocouple readouts, pressure gauges, temperature transmitters, digital process simulators, data loggers, and multimeters.\u003c\/li\u003e\n\u003cli\u003eEnhanced calibration range: 24 V DC transmitter loop power supply and measures 4-20 mA loop current.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003ch2\u003eModels: 7526A Precision Process Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003e7526A\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-0\" class=\"model-desc\"\u003e\n\u003cp\u003ePrecision Process Calibrator\u003c\/p\u003e\n\u003c\/div\u003e\nIncludes traceable calibration report, user manual CD, getting started guide, power cord, thermocouple shorting jumper and USB-to-serial adapter cable.\u003c\/div\u003e\n\u003cdiv class=\"pricespider\"\u003e\n\u003cdiv id=\"0\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion\"\u003e\n\u003cspan class=\"upc\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003ch1\u003e\n\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"”head”\"\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDC voltage, output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty, ±\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(ppm of output + μV), 1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to 100 mV\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to 1 V\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to 100 V\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003eTC Output and Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e–10 mV to 75 mV\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e2 μV\u003c\/td\u003e\n\u003ctd\u003e1 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e[1] All outputs are positive only unless otherwise noted\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDC voltage, isolated input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty, ±\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(ppm of reading + mV),\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to 10 V\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003ctd\u003e100 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 V to 100 V\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDC Current, output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e± (ppm of reading + μA),\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 to 100 mA\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e[1] For line voltages less than 95 V, ±100 ppm of reading\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eDC current, isolated input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty, ±\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(ppm of reading + μA),\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 mA to 50 mA\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 mA to 24 mA \u003csup\u003e[1][2]\u003c\/sup\u003e\u003cbr\u003e(Loop Power)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e[1] Loop Power: 24 V ±10%\u003cbr\u003e[2] HART Resistor: 250 Ω ± 3%\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eResistance, output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAbsolute\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eUncertainty,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003etcal ± 5 °C, ±\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOhms, 1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNominal\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ecurrent\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd\u003e0.015\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω\u003c\/td\u003e\n\u003ctd\u003e1 to 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 Ω to 4 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.3\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd\u003e100 μA to 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eResistance, input\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty, ±\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(ppm of reading + Ω), 1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e0.004\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 Ω to 4 kΩ\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e0.04\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cstrong\u003eSample thermocouple accuracy, input\/output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(does not include all available TC types)\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eTC type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature Range (°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003etcal ±5 °C, ± (°C), 1-yr \u003csup\u003e[2]\u003c\/sup\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMax\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e-210\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003ctd\u003e0.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e-250\u003c\/td\u003e\n\u003ctd\u003e1372\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS\u003c\/td\u003e\n\u003ctd\u003e-50\u003c\/td\u003e\n\u003ctd\u003e1767\u003c\/td\u003e\n\u003ctd\u003e0.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003e-250\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e0.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e[1] See extended specifications for all TC types (B,C,E,J,K,L,N,R,S,T,U,XK,BP)\u003cbr\u003e[2] Best accuracy within specified TC temperature range\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cstrong\u003eSample RTD and thermistor, output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(does not include all available RTD types)\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eRTD Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature Range (°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003etcal ±5 °C, ± (°C), 1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMax\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePt 385, 100 Ω\u003c\/td\u003e\n\u003ctd\u003e-200\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYSI 400\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e[1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cstrong\u003eSample RTD and thermistor, intput\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(does not include all available RTD types)\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eRTD Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature Range (°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cstrong\u003eAbsolute Uncertainty,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003etcal ±5 °C, ± (°C), 1-yr\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMax\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003ePt 385, 100 Ω\u003c\/td\u003e\n\u003ctd\u003e–80\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e0.020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e0.024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003e0.038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYSI 400\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e0.007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e[1] See extended specifications for all RTD types: Pt-100 (385, 3926, 3916), Pt- 200, Pt-500, Pt-1000, Ni-120, Cu-427, SPRT\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRS-232, IEEE-488 (GPIB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eperformance\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eOperating:\u003c\/td\u003e\n\u003ctd\u003e0 °C to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration (tcal):\u003c\/td\u003e\n\u003ctd\u003e18 °C to 28 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage:\u003c\/td\u003e\n\u003ctd\u003e–20 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eElectromagnetic\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ecompatibility\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE: Conforms to EN61326;\u003cbr\u003eoperation in controlled EM environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTemperature coefficient for temperatures\u003cbr\u003eoutside tcal 5 °C is 10% of the 90-day\u003cbr\u003especification (or 1 year if applicable) per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eOperating:\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;80% to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026lt;70% to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026lt;40% to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating:\u003c\/td\u003e\n\u003ctd\u003e3,000 m (9,800 ft) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating:\u003c\/td\u003e\n\u003ctd\u003e12,200 m (40,000 ft) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN\/IEC 61010-1:2010 3rd Edition,\u003cbr\u003eUL 61010-1:2012, CAN\/CSA 22.2 No. 61010-1-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog low isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eLine power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 V~:\u003c\/td\u003e\n\u003ctd\u003e100 V to 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 V~:\u003c\/td\u003e\n\u003ctd\u003e220 V to 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e47 Hz to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine voltage variation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 10 % about setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeight:\u003c\/td\u003e\n\u003ctd\u003e14.6 cm (5.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth:\u003c\/td\u003e\n\u003ctd\u003e44.5 cm (17.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth:\u003c\/td\u003e\n\u003ctd\u003e29.8 cm (11.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(without options)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.24 kg (9.35 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":56200168931650,"sku":null,"price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/Fluke_7526A_Precision_Process_Calibrator.png?v=1789703362","url":"https:\/\/antletstech.com\/products\/fluke-52-ii-dual-probe-digital-thermometer-%e5%89%af%e6%9c%ac","provider":"ANTLETS","version":"1.0","type":"link"}