{"product_id":"abb-electromagnetic-flowmeter-hygienicmaster-feh610","title":"ABB Electromagnetic flowmeter HygienicMaster FEH610","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eHygienicMaster FEH610 is designed specifically for the food \u0026amp; beverage industries in a cost-effective, robust package.\u003cbr\u003e\u003cbr\u003eThe sensor is fully CIP\/SIP cleanable, manufactured from FDA approved materials and certified with 3A.\u003cbr\u003e\u003cbr\u003eAvailable as an integral or remote mount design – with or without local LCD display. All versions use a common transmitter with easy to understand diagnostic message for improved operator efficiency.\u003cbr\u003e\u003cbr\u003eHygienicMaster FEH610´s variable process connections simplify installation and reduce inventory and replacement costs.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHygienicMaster FEH610 is ideally suited for hygienic standard applications featuring all functions required - no more and no less.\u003cbr\u003e\u003cbr\u003eThe perfect device for everyday applications.\u003cbr\u003e\u003cbr\u003eSimple and economical.   \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eField-proven powerful and flexible transmitter technology\u003cbr\u003e– ABB common HMI concept\u003cbr\u003e– Easy Set-up function for simple and intuitive configuration\u003cbr\u003e– Through-the-glass operation  \u003c\/li\u003e\n\u003cli\u003eOne single transmitter for all design types\u003cbr\u003e– Integral mount design or remote mount design\u003cbr\u003e– With or without local LCD display\u003cbr\u003e– Universal wide range power supply\u003cbr\u003e– 1 analog output, 2 digital outputs\u003c\/li\u003e\n\u003cli\u003eRobust construction for rough environmental conditions \u003cbr\u003e– Hermetically sealed flow sensor\u003cbr\u003e– Protection of the inside components against\u003cbr\u003e      Condensation, vibration and corrosion\u003cbr\u003e      Damages during transport and mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHygienic and Reliable Measurement\u003c\/strong\u003e\u003cbr\u003eDesigned for applications requiring strict hygiene standards and reliable flow measurement.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Cleaning and Maintenance\u003c\/strong\u003e\u003cbr\u003eSupports hygienic process requirements including CIP\/SIP cleaning procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCost-Effective Hygienic Solution\u003c\/strong\u003e\u003cbr\u003eProvides reliable performance for standard food, beverage and pharmaceutical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation\u003c\/strong\u003e\u003cbr\u003eMultiple hygienic connection options simplify integration into process systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance Effort\u003c\/strong\u003e\u003cbr\u003eNo moving parts design minimizes wear and improves long-term reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable Process Control\u003c\/strong\u003e\u003cbr\u003eProvides consistent measurement performance for conductive liquids.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eitem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003evalue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eaccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% of rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003etype\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHygienic Electromagnetic Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ebrand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emodel number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFEH610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Inductive Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConductive Liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eflow measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eVolume Flow Measurement of Hygienic Liquid Media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasuring principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFaraday's Law of Electromagnetic Induction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003enominal diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDN 3 to DN 100 (1\/8 to 4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eoutput signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA; Pulse\/Frequency Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecommunication protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHART (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic Display (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eThrough-The-Glass (TTG) Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003elocal operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration via Local Display and Touch Control (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eelectronics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eModular Transmitter Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003etransmitter design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact Mount or Remote Mount Version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ediagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic Device Diagnostics; Empty Pipe Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eprocess connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHygienic Connections: Tri-Clamp, Threaded Connections, Welded Ends and Other Hygienic Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eliner material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePFA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eelectrode materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003efluid temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 140 °C (284 °F) (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epressure rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eprotection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 \/ IP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56221218242882,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Electromagnetic_flowmeter_HygienicMaster_FEH610.png?v=1789983389","url":"https:\/\/antletstech.com\/products\/abb-electromagnetic-flowmeter-hygienicmaster-feh610","provider":"ANTLETS","version":"1.0","type":"link"}