{"product_id":"abb-electromagnetic-flowmeter-aquamaster-few450","title":"ABB Electromagnetic flowmeter AquaMaster FEW450","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eAquaMaster4: Redefining Flow Measurement.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAquaMaster4 is the ultimate solution for managing District Meter Areas (DMAs) in water distribution networks. From leakage monitoring to revenue metering and survey investigations, it delivers precision you can trust.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvery drop, measured with confidence.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for modern water applications, AquaMaster4 combines flow and pressure measurement with an integrated logger and cellular engine. Powered by a long-life battery lasting up to 11 years, it ensures secure, reliable, and worldwide data transmission. Keeping you connected wherever you are.\u003c\/p\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eSolution from the masters of flow measurement – in 1988, ABB invented and designed the world's first battery-powered electromagnetic flowmeter for DMA (District Metered Area)\u003c\/li\u003e\n\u003cli\u003eInvest smartly through 'single box' DMA solution – combining flow, pressure and data-logging with inbuilt cellular engine.\u003c\/li\u003e\n\u003cli\u003eHave greatest confidence in your billing based on highest accuracy with widest flow range revenue meter\u003c\/li\u003e\n\u003cli\u003eGet early warnings for leaks or bursts and reduce NRW (Non-Revenue Water) – highest confidence in night line performance\u003c\/li\u003e\n\u003cli\u003eHave highest confidence in the wet calibration – our flow rigs are certified by various national independent accredited bodies \/ laboratories all linked by the 'International Laboratory Accreditation Cooperation' (ILAC)\u003c\/li\u003e\n\u003cli\u003eFit and flow with factory default settings. To customize minimal on-site configuration required with quick and easy configuration through ABB Velox mobile smart phone \/ tablet app\u003c\/li\u003e\n\u003cli\u003eLowest total cost of ownership (TOTEX) over complete product lifecycle. AquaMaster conforms to the latest international standards to meet increasing legislative demands for accurate flow metering. Its wide measuring range ensures peak daytime flows are accurately recorded and its exceptional low flow performance aids network leak detection.\u003c\/li\u003e\n\u003cli\u003eFit and flow for foolproof installation, all data is stored in the sensor to reduce on-site setup. AquaMaster's unique sensor design conditions the flow profile resulting in excellent meter performance in poor hydraulic installation conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEW450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAquaMaster4 Mobile Comms Electromagnetic Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWater and Wastewater Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFaraday’s Law of Electromagnetic Induction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrically Conductive Liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow Rate, Flow Velocity, Volume Flow (Forward, Reverse and Net), Pressure Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to ±0.2% of Rate ±0.5 mm\/s (Whichever is Greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to R1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReduced Bore DN40 to DN600; Full Bore DN40 to DN2400; Probe DN300 to DN1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReduced Bore, Full Bore and Probe Versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse \/ Modbus Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4G LTE \/ NB-IoT Cellular Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFTPS \/ MQTTS Secure Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery Powered, Renewable Energy or AC Mains (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 11 Years (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal Display with Contactless Configuration Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB Velox Interface via NFC Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Data Logger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudit Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Audit Log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Update\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver-The-Air (OTA) Firmware Upgrade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIn-Situ Diagnostics and Self-Checking Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuitable for Submersible and Buried Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68 (NEMA 6P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlanged Connections According to International Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Cellular Communication, Remote Data Access, OTA Firmware Upgrade, Secure Data Transmission, High Accuracy Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWater Distribution Networks, District Metering Areas (DMA), Leakage Monitoring, Revenue Metering, Wastewater Treatment and Irrigation Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56250557727042,"sku":null,"price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Electromagnetic_flowmeter_AquaMaster_FEW450.png?v=1790216024","url":"https:\/\/antletstech.com\/products\/abb-electromagnetic-flowmeter-aquamaster-few450","provider":"ANTLETS","version":"1.0","type":"link"}