{"product_id":"abb-coriolis-mass-flowmeter-coriolismaster-fcd450","title":"ABB Coriolis mass flowmeter CoriolisMaster FCD450","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eWith no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.\u003cbr\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eThe FCD400 series delivers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"sfContentBlock\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eUp to five modular I\/Os\u003c\/p\u003e\n\u003cp\u003e– Multivariable meter design\u003c\/p\u003e\n\u003cp\u003e– Optional plug-in cards\u003c\/p\u003e\n– Automatic firmware update\u003cbr\u003e– Various communication protocols available:\u003cbr\u003e   EthernetIP, Modbus TCP, Web Browser and Profinet\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eStandard Ethernet and Ethernet APL\/SPE Connectivity\u003cbr\u003e– Protocols supported: Ethernet IP, Profinet, Modbus TCP\u003cbr\u003e– For remote access to built-in diagnostic monitoring the flowmeter and your process\u003cbr\u003e– Flowmeter verification and configuration over Ethernet minimizing commissioning time\u003cbr\u003e– Built-in webserver, no additional software required for flowmeter configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSmartSensor\u003cbr\u003e– All digital solution\u003cbr\u003e– Installation flexibility\u003cbr\u003e– Meter intelligence located in the sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSensorApplicationMemory\u003cbr\u003e– Maximum data security\u003cbr\u003e– Plug and play electronics replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eABB common look and feel\u003cbr\u003e– Easy Set-up\u003cbr\u003e– Operation through the glass via capacitive keys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eVeriMass on-board verification and diagnostics\u003cbr\u003e– Online preventive maintenance\u003cbr\u003e– Extended maintenance cycles\u003cbr\u003e– Reduced maintenance effort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 70 °C (158 °F) ambient temperature and high vibrations\u003c\/li\u003e\n\u003cli\u003eEnhanced Coriolis control (ECC) option for advanced measurement for multiphase conditions and other challenging fluids\u003c\/li\u003e\n\u003cli\u003eLow pressure drop\u003c\/li\u003e\n\u003cli\u003eSelf-draining\u003c\/li\u003e\n\u003cli\u003eGlobal approvals for explosion protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe FCD450 adds:\u003c\/strong\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDensiMass software for direct concentration measurement\u003c\/li\u003e\n\u003cli\u003eFillMass software for filling application control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThe ideal transmitter for system integration \u003c\/strong\u003e\u003cbr\u003e• Modbus for quick and comprehensive communication \u003cbr\u003e• Two fast digital outputs that can be configured as pulse outputs, \u003cbr\u003efrequency outputs or binary outputs \u003cbr\u003e• Lower pressure loss, self-draining \u003cbr\u003e• Global approvals for explosion protection \u003cbr\u003e• MID \/ OIML approval for legal metrology \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eIntegrated VeriMass device verification and diagnosis \u003c\/strong\u003e\u003cbr\u003e• Predictive maintenance in the process \u003cbr\u003e• Extended maintenance cycles \u003cbr\u003e• Reduced maintenance effort \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoriolisMaster Software Tools \u003c\/strong\u003e\u003cbr\u003e• DensiMass for concentration measurements, net mass and volume flow calculations \u003cbr\u003e• FillMass for filling applications\u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCD450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolisMaster Low Flow Coriolis Mass Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolis Mass Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolis Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquids, Gases and Steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow, Volume Flow, Density and Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow: ±0.1% of Rate; Volume Flow: ±0.15% of Rate; Density: 10 g\/l, 5 g\/l or 1 g\/l (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN8 (5\/16 in.) and DN10 (3\/8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN8: 0 to 600 kg\/h; DN10: 0 to 2,500 kg\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Output, Digital Outputs, Pulse\/Frequency Output (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART; PROFIBUS DP\/PA; Modbus RTU; Ethernet Communication (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 to 30 V DC; 100 to 230 V AC; Power over Ethernet (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral Mount or Remote Mount Version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThreaded Connections and Flanged Connections (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel 1.4404 \/ 1.4435 (316L); Hastelloy C (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 to +220 °C (-58 to +428 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to +70 °C (+158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Upstream or Downstream Straight Pipe Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP67 \/ IP68 (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVeriMass On-Board Verification and Device Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConcentration Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDensiMass Software for Direct Concentration Measurement (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilling Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFillMass Software for Filling Application Control (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnhanced Measurement Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnhanced Coriolis Control (ECC) Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Ethernet \/ Ethernet-APL (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh Precision Low Flow Measurement, Multivariable Measurement, Compact Design, Advanced Diagnostics, Flexible Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGas Measurement, Chemical Dosing, Fuel Consumption Measurement, Filling Systems, Laboratory Applications and General Industrial Processes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56253349134658,"sku":null,"price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/Coriolis_mass_flowmeter_CoriolisMaster_FCD450.png?v=1790231147","url":"https:\/\/antletstech.com\/products\/abb-coriolis-mass-flowmeter-coriolismaster-fcd450","provider":"ANTLETS","version":"1.0","type":"link"}