Endress+Hauser 5W4C Proline Promag W400 Electromagnetic Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Precio habitual Oferta

OverviewEndress+Hauser Proline Promag W400 Electromagnetic Flowmeter is a versatile standard flowmeter for the water and wastewater industry.Specs at a glanceMax. measurement error Volume flow (standard): ±0.5 % o.r....

Overview

Endress+Hauser Proline Promag W400 Electromagnetic Flowmeter is a versatile standard flowmeter for the water and wastewater industry.

Specs at a glance

Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec Measuring range 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Field of application

With its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water & Wastewater. In addition, Heartbeat Technology enables measurement reliability and compliant verification.

* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
* Ideal for water measurement , e.g. drinking water, utility water and industrial/municipal wastewater


Device properties
* International drinking water approvals
* Degree of protection IP68 (Type 6P enclosure)
* Approved for custody transfer to MI-001/OIML R49
* Transmitter housing made of durable polycarbonate or aluminium
* WLAN access
* Integrated data logger: measured values monitoring 
 

Benefits

 * Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss
* Flexible engineering – sensor with fixed or lap-joint process connections
* Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
* Improved plant availability – sensor compliant with industry-specific requirements
* Safe operation – no need to open the device
* Time-saving local operation without additional software and hardware – integrated web server
* Integrated verification and build-up detection – Heartbeat Technology

Specification

Model Number Proline Promag W 300
Measuring principle Electromagnetic 
 
Product headline Versatile standard flowmeter for the water and wastewater industry. 
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss. 
Ideal for water measurement, e.g. drinking water, utility water and industrial/municipal wastewater.
Sensor features Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection 
for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. 
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). Approved for custody transfer to 
MI-001/OIML R49.
Transmitter features Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation 
without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. 
Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring.
Nominal diameter range DN 25 to 3000(1 to 120")
Wetted materials Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) 
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) 
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measured variables Volume flow, conductivity, mass flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) 
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Measuring range 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Max. process pressure PN 40, Class 300, 20K
Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) 
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Ambient temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Sensor housing material DN 25 to 300 (1 to 12"): AlSi10Mg, coated 
DN 25 to 3000 (1 to 78"): Carbon steel with protective varnish 
Sensor connection housing (standard): AlSi10Mg, coated 
Sensor connection housing (option): Polycarbonate
Transmitter housing material Polycarbonat; AlSi10Mg, coated
Degree of protection Compact version: IP66/67, type 4X enclosure 
Sensor remote version (standard): IP66/67, type 4X enclosure 
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish 
according to EN ISO 12944 C5‐M/Im1/Im2/Im3 
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside) 
Configuration via local display, web browser and operating tools possible
Outputs 3 ouputs: 
0‐20 mA/4‐20 mA HART (active) 
Pulse/frequency/switch output (passive) 
Pulse/frequency output (passive) 
Switch output (passive)
Inputs Status input
Digital communication HART, PROFIBUS DP, EtherNet/IP, Modbus RS485
Power supply AC 100…240 V / AC/DC 24 V
Hazardous area approvals cCSAus
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR 
Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.