Endress+Hauser Hydrostatic Level Measurement Deltapilot FMB50

: In stock

: Level Measurement

: Endress+Hauser

Precio habitual Oferta

Overview Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement. Specs at a glance * Accuracy :Standard 0.2% Optional 0.1%* Process temperature :-10°C...100°C (14°F...212°F)* Pressure...


Overview

Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement.

Specs at a glance

* Accuracy :Standard 0.2% Optional 0.1%
* Process temperature :-10°C...100°C (14°F...212°F)
* Pressure measuring range :100 mbar...10 bar (1.5 psi...150 psi)
* Process pressure / max. overpressure limit : 40 bar (600 psi)
* Main wetted parts : Alloy C 316L optional coating AuPt
* Max. measurement distance :100m (328ft) H2O
* Material process membrane : 316L, AlloyC Gold-Rhodium
* Measuring cell : 100 mbar...10 bar (1.5 psi...150 psi)


Benefits

 * Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
* Modular concept for easy replacement of display or electronics
* Seamless and independent system integration (HART/PA/FF)
* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
* International usage thanks to a wide range of approvals

Application

The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications.It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.For level and/or pressure measurement.
* Process connections: Thread, flanges and flush-mounted hygienic connections
* Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
* Measuring range: 0.1 to 10bar (1.5 to 150psi)
* Accuracy: ±0.2%, ±0.1% (option)
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates

Specification

Measuring principle
Hydrostatic pressure
Characteristic
Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Supply voltage
4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Reference Accuracy
Standard 0.2 %
Optional 0.1 %
Long term stability
0.05 % of URL/ year
Process temperature
-10°C...100°C
(14°F...212°F)
Ambient temperature
-40°C...85°C
(-40°F...185°F)
Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Smallest calibratable span
10 mbar (1.45 psi)
Vacuum resistance
0 mbar abs.
Max. Turn down
100:1
Max. overpressure limit
40 bar (600 psi)
Process connection
Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 1 1/2"...4",
JIS 10K
Process connection hygienic
Tri-Clamp
DIN11851
DIN11864-1
NEUMO
Varivent N
SMS
DRD
Material process membrane
316L, AlloyC
Gold-Rhodium
Material gasket
None, measuring cell welded
Fill fluid
Inert oil,
Synthetic oil
Material housing
316L, Die-cast aluminum
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
IO-Link
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals
Overfill protection WHG
SIL
Design approvals
EN10204-3.1
NACE MR0103
Hygienic approvals
3A, EHEDG
CoC ASME-BPE
Marine approvals
GL/ ABS/ LR/ BV/ DNV
Drinking water approvals
KTW/ NSF/ ACS
Specialities
Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions
please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.