{"product_id":"fluke-1507-insulation-resistance-tester","title":"Fluke 1507 Insulation Resistance Tester","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003eProduct overview: Fluke 1507 Insulation Resistance Tester\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003ch3\u003eOther useful capabilities:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-list-item-id=\"e9a78548704f97bab47a7a005c442ce9f\"\u003ePerforms insulation tests from 0.01 MΩ to 10 GΩ\u003c\/li\u003e\n\u003cli data-list-item-id=\"eef4f39c2439213e19a8c10e0abd909a6\"\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli data-list-item-id=\"e20a7a143816c0502f0e4a918c0137339\"\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli data-list-item-id=\"ef32845add444107ff69f317f521f4577\"\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli data-list-item-id=\"e4fd9d9486f48054abbc510a9b477038b\"\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli data-list-item-id=\"ee7f0b91e8b50db0d8482281100e4d660\"\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli data-list-item-id=\"ed95e10f08dd2cdc04cf3de872e6e2012\"\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli data-list-item-id=\"e1e6b85f1817a9ad4a140aa713d15c3e2\"\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli data-list-item-id=\"ea29740a2121d4d01e6e2abe9d5b2d507\"\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli data-list-item-id=\"e870622261c7fc8dc9b04e1c9c7124705\"\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003cli data-list-item-id=\"eb81ab624e70dc53dc69735951db15784\"\u003eAccepts optional Fluke TPAK magnetic hanging system to free your hands for other work\u003c\/li\u003e\n\u003cli data-list-item-id=\"e66ce76bb093d008029b0394957088e45\"\u003eRuns on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003ch2\u003eModels: Fluke 1507 Insulation Resistance Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFluke 1507\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5066006\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1507 Insulation Resistance Tester\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5066006\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 28867 5\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFluke 1507 CAL\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-5160560\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 1507 Insulation Resistance Tester, with a traceable certificate of calibration with data from Fluke\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 5160560\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 94682 7\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003cli\u003eA traceable certificate of calibration with data from Fluke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"pricespider\"\u003e\n\u003cdiv id=\"0\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion\"\u003e\n\u003cspan class=\"upc\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003ch1\u003e\n\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20.00 Ω\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation test use:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":68212311556418,"sku":null,"price":770.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/Fluke_1507_Insulation_Resistance_Tester_5.png?v=1794820650","url":"https:\/\/antletstech.com\/es\/products\/fluke-1507-insulation-resistance-tester","provider":"ANTLETS","version":"1.0","type":"link"}