{"product_id":"fluke-114-electrical-multimeter-副本","title":"Fluke 113 Digital Multimeter","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003eProduct overview: Fluke 113 Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"overview-grid\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003cp\u003eThe Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic testing. It is easy to use and is packed with the features needed to repair most electrical problems. The 113 features a large, backlit display for easy visibility in low-lit work environments. Plus, the integrated holster includes probe holders on the back, so your test leads can always be kept organized and where you need them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMake measurements quickly with the 113\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhether you’re a utility worker, linesman, electrician, technician, anyone else working with basic electrical testing, the Fluke 113 includes the measurement features you need to tackle your job. The Fluke VCHEK™ LoZ low impedance measurement function lets users perform tests for voltage or continuity from the same dial position.\u003c\/p\u003e\n\u003cp\u003ePlease note that low impedance LoZ measurements will cause a low load on a circuit protected by a RCD, which will trip powered GFCI and RCD circuits when measuring Phase to Earth.\u003c\/p\u003e\n\u003cp\u003eThe meter also displays AC or DC voltage, depending on what was detected, while also rejecting ghost voltages from adjacent wires.  If no voltage is detected, a continuity test is performed. The Min\/Max function lets you record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 113 digital multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecial features\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eVCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.\u003c\/li\u003e\n\u003cli\u003eLarge backlit display\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V safety rated\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModels: Fluke 113 Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\"\u003eFluke 113\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"model-3078875\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 113 Digital Multimeter\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 3078875\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 43452 2\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke TL75 test leads\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eUsers manual\u003c\/li\u003e\n\u003cli\u003eand 9 V battery (installed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion\"\u003e\n\u003cdiv class=\"model-name\"\u003eR-FLUKE-113\u003c\/div\u003e\n\u003cdiv id=\"model-4390552\" class=\"model-desc\"\u003e\n\u003cp\u003eFluke 113 Digital Multimeter, fully reconditioned to original factory specifications. Includes Fluke's 3 year product warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"sku\"\u003ePart#: 4390552\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"upc\"\u003eUPC#: 0 95969 68811 6\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"fluke-product-display-models\"\u003e\n\u003cdiv id=\"Product-models\"\u003e\n\u003cdiv class=\"ig-product-models\" id=\"ig-product-models\"\u003e\n\u003cdiv class=\"product-model\"\u003e\n\u003cdiv class=\"accordion\"\u003e\u003cspan class=\"upc\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable class=\"table\" style=\"width: 100%; height: 1214.81px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 96.1062%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"3\" style=\"width: 35.1244%; height: 78.3751px;\"\u003eVCHEK\u003csup\u003e1 2 3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e6.000 V \/ 60.00 V \/ 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e0.001 V \/ 0.01 V\/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 39.1875px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 39.1875px;\"\u003eDC, 45 to 500 Hz: 2.0% + 3\u003cbr\u003e500 Hz to 1 kHz: 4.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"3\" style=\"width: 35.1244%; height: 58.7814px;\"\u003eDiode test\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e2.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 58.7812px;\"\u003eContinuity\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 58.7812px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 58.7812px;\"\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of 500 μs or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"3\" style=\"width: 35.1244%; height: 58.7814px;\"\u003eΩ\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e600.0 Ω \/ 6.000 kΩ \/ 60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e0.1 Ω \/ 0.001 kΩ \/ 0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e0.9% + 2 \/ 0.9% + 1 \/ 0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd rowspan=\"3\" style=\"width: 35.1244%; height: 117.562px;\"\u003eCapacitance\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 39.1875px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 39.1875px;\"\u003e1000 nF \/ 10.00 μF \/ 100.0 μF \/ 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e1 nF \/ 0.01 μF \/ 0.1 μF \/ 1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 58.7812px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 58.7812px;\"\u003e1.9% + 2\u003cbr\u003e100 μF - 1000 μF: 1.9% + 2\u003cbr\u003e1000 μF: 5% + 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 176.344px;\"\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\" style=\"width: 96.1062%; height: 176.344px;\"\u003e1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.\u003cbr\u003e2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.\u003cbr\u003e3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.\u003cbr\u003e4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\" style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 96.1062%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 39.1875px;\"\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 39.1875px;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e3 3\/4-digits, 6000 counts, updates 4\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e-40°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e0.1 x (specified accuracy) \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e10,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 58.7812px;\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 58.7812px;\"\u003e95% to 30°C\u003cbr\u003e75% to 40°C\u003cbr\u003e45% to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e9 Volt Alkaline, IEC 6F22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003eAlkaline: 300 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003e13.0 oz (404 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 39.1875px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 39.1875px;\"\u003eIEC 61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eEMI regulations\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 60.9818%; height: 19.5938px;\"\u003eComplies with FCC Part 15, Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\" style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 96.1062%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 39.1875px;\"\u003eVCHEK\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 39.1875px;\"\u003e\u003cstrong\u003eInput impedance (nominal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 39.1875px;\"\u003e~3 kΩ \u0026lt; 300 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 58.7812px;\"\u003eVCHEK\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 58.7812px;\"\u003e\n\u003cstrong\u003eCommon mode rejection ratio\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(1 kΩ unbalanced)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 58.7812px;\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd rowspan=\"2\" style=\"width: 35.1244%; height: 58.7813px;\"\u003eΩ\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 39.1875px;\"\u003e\u003cstrong\u003eOpen circuit test voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 39.1875px;\"\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eFull scale voltage\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e\u0026lt; 0.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd rowspan=\"2\" style=\"width: 35.1244%; height: 58.7813px;\"\u003eDiode test\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 39.1875px;\"\u003e\u003cstrong\u003eOpen circuit test voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 39.1875px;\"\u003e2.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003eFull scale voltage\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e2.000 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eΩ\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003e\u003cstrong\u003eShort circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e\u0026lt; 350 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 35.1244%; height: 19.5938px;\"\u003eDiode test\u003c\/td\u003e\n\u003ctd style=\"width: 24.4552%; height: 19.5938px;\"\u003e\u003cstrong\u003eShort circuit current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 36.5265%; height: 19.5938px;\"\u003e\u0026lt; 1.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"FLUKE","offers":[{"title":"Default Title","offer_id":56147162792258,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/Fluke_113_Digital_Multimeter.png?v=1789038269","url":"https:\/\/antletstech.com\/es\/products\/fluke-114-electrical-multimeter-%e5%89%af%e6%9c%ac","provider":"ANTLETS","version":"1.0","type":"link"}