{"product_id":"abb-electromagnetic-flowmeter-processmaster-fep300","title":"ABB Electromagnetic flowmeter ProcessMaster FEP300","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eThe modular design of the ProcessMaster FEP300 standard version offers the industry's widest range of liners electrodes and sizes to meet the needs of even the most demanding process applications in sectors as diverse as chemical, power, oil \u0026amp; gas, pulp \u0026amp; paper and metals \u0026amp; mining.\u003c\/p\u003e\n\u003cp\u003eAvailable as integral mount design or remote mount design system.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe powerful transmitter is easy to use and provides the output signal that meets the needs.\u003cbr\u003e\u003cbr\u003eProcessMaster FEP300 is a versatile, reasonably priced, most accurate flow meter tailored for all process industry applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation.   \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile and simple configuration\u003cbr\u003e– Through glass configuration eliminating the need to remove the cover and reducing commissioning time\u003cbr\u003e– Soft key based functionality\u003cbr\u003e– \"Easy Set-up\" function  \u003c\/li\u003e\n\u003cli\u003eState-of-the-art memory technology\u003cbr\u003e– Data storage enables transmitter exchange without the need for reconfiguration\u003c\/li\u003e\n\u003cli\u003eDiagnostics for real-life-situations \u003cbr\u003e– Simplified plant trouble shooting\u003cbr\u003e– Status messages in accordance with NAMUR\u003cbr\u003e– Help texts in LCD display\u003c\/li\u003e\n\u003cli\u003eScanMaster in situ verification software option\u003cbr\u003e– Allows the customer to perform in situ verification of the flowmeter and the plant \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable and Accurate Measurement\u003c\/strong\u003e\u003cbr\u003eProvides stable flow measurement performance for a wide range of conductive liquid applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Configuration Options\u003c\/strong\u003e\u003cbr\u003eSupports multiple sizes, liners, electrodes and process connections to meet different industrial requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Commissioning and Maintenance\u003c\/strong\u003e\u003cbr\u003eEasy Set-up function and data storage technology reduce installation and service time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostic Capability\u003c\/strong\u003e\u003cbr\u003eHelps improve plant availability through device monitoring and troubleshooting functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Industrial Application Range\u003c\/strong\u003e\u003cbr\u003eSuitable for demanding process industries including chemical, oil \u0026amp; gas, power, water and wastewater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance Costs\u003c\/strong\u003e\u003cbr\u003eNon-moving-part design minimizes mechanical wear and improves long-term reliability.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eitem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003evalue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eaccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4% of rate (Standard); Optional ±0.2% of rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003etype\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eElectromagnetic Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ebrand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emodel number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic Inductive Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConductive Liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eflow measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eVolume Flow Measurement of Liquid Media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emeasuring principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFaraday's Law of Electromagnetic Induction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003enominal diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDN 3 to DN 2000 (1\/10 to 80 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eoutput signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable Current Output, Pulse\/Frequency Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecommunication protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHART; PROFIBUS PA; FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eThrough-The-Glass (TTG) Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003elocal operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration without Opening the Housing via Soft Keys and Easy Set-up Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eelectronics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Transmitter Design with Data Storage Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003etransmitter design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact Mount Design or Remote Mount Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ediagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEmpty Pipe Detection; Partial Filling Detection; NAMUR Status Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003everification function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABB Ability™ Verification \/ ScanMaster In-Situ Verification Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eprotection rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP67; IP68 (Remote Mount Design Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eprocess connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange Connection according to DIN EN 1092-1, ASME B16.5\/B16.47, JIS, AS2129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003enominal pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePN 10 to PN 100; ASME Class 150, 300, 600, 900, 1500, 2500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eliner materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHard Rubber, Soft Rubber, PTFE, PFA, ETFE, Linatex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eelectrode materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eexplosion protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, FM, cFM, NEPSI, GOST (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ehousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent (Compact or Remote Version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003efeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEasy Set-up, TTG Configuration, Advanced Diagnostics, Data Storage and Flexible Material Selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eapplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess Flow Measurement in Chemical, Oil \u0026amp; Gas, Power, Water, Pulp \u0026amp; Paper and Metals \u0026amp; Mining Industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56220947579202,"sku":null,"price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Electromagnetic_flowmeter_ProcessMaster_FEP300.png?v=1789981550","url":"https:\/\/antletstech.com\/es\/products\/abb-electromagnetic-flowmeter-processmaster-fep300","provider":"ANTLETS","version":"1.0","type":"link"}