{"product_id":"abb-differential-pressure-transmitter-266mst-副本","title":"ABB Multivariable transmitter 266CSH","description":"\u003cstyle\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:73px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:73px}#detail_decorate_root .magic-5{overflow:hidden;width:750px;height:350px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-6{margin-top:-142px;margin-left:34px;width:676px;height:676px}#detail_decorate_root .magic-7{font-size:22px}#detail_decorate_root .magic-8{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-9{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-10{width:750px;border-collapse:collapse}#detail_decorate_root .magic-11{min-height:28px;padding:5px 10px;width:259px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-12{min-height:28px;padding:5px 10px;width:442px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-13{vertical-align:top}#detail_decorate_root .magic-14{vertical-align:top;display:inline-block;padding-right:4px;width:50%;box-sizing:border-box;margin-bottom:-4px;padding-left:4px;margin-top:-4px}#detail_decorate_root .magic-15{padding:0;margin:0}#detail_decorate_root .magic-16{padding:0;margin:0;color:#333;font-size:14px;line-height:20px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-17{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-18{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-19{white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-20{overflow:hidden;width:750px;height:210.99434114793857px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-21{margin-top:0;margin-left:0;width:750px;height:210.99434114793857px}#detail_decorate_root .magic-22{overflow:hidden;width:750px;height:385.17745302713985px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-23{margin-top:0;margin-left:0;width:749.9999999999999px;height:385.17745302713985px}#detail_decorate_root .magic-24{overflow:hidden;width:750px;height:528.4446764091857px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-25{margin-top:0;margin-left:0;width:749.9999999999999px;height:528.4446764091857px}#detail_decorate_root .magic-26{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-27{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-28{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-29{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-30{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-31{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-32{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-33{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-34{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-35{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-36{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-37{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-38{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-39{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-40{margin-top:0;margin-left:0;width:750px;height:76px}#detail_decorate_root .magic-41{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}\u003c\/style\u003e\n\u003cdiv id=\"detail_decorate_root\"\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"icbu-pc-images magic-0\"\u003e\n\u003cdiv class=\"flex-layout-v\"\u003e\n\u003cdiv class=\"flex-layout-h magic-0\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"icbu-pc-images magic-0\"\u003e\n\u003cdiv class=\"text-wrapper-below text-theme-light text-align-left\"\u003e\n\u003cdiv class=\"text-title\"\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"sfContentBlock\"\u003e\n\u003cp\u003e\u003cspan\u003eThe multivariable transmitters in the 266CSH are used for differential pressure flow measurements. Apart from pressure- and \/ or temperature-dependent changes to the density of the fluid, the parameters such as the discharge coefficient, thermal expansion of pipelines and primary device and the Reynolds number are also corrected. It can also be used for DP level measurement if density compensation is necessary due to process temperature changes. This could make any level measurement much more reliable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn addition to high precision, the multivariable 266 also offers the advantage that only a single device needs to be used for the measuring point instead of several transmitters and a flow calculator.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cstrong\u003eBase accuracy\u003c\/strong\u003e\u003cbr\u003e• 0.075 % of calibrated span (266CSH, 266JSH)\u003cbr\u003e• 0.04 % of calibrated span (266CST, 266JST)\u003cbr\u003e266CSH\/CST mass flow measurement with compensation, level measurement with compensation for gases, steam and liquids\u003cbr\u003e• Dynamic compensation of pressure and temperature changes\u003cbr\u003e266JSH\/JST high-performance transmitter for measuring differential  pressure, absolute pressure and process temperature in a single device\u003cstrong\u003e\u003cbr\u003eProven sensor technology together with state-of-the-art digital technology\u003c\/strong\u003e\u003cbr\u003e• Large turn down ratio of up to 100:1\u003cbr\u003e\u003cstrong\u003eComprehensive range of functions\u003c\/strong\u003e\u003cbr\u003e• Integrated counting function\u003cbr\u003e• Binary output as pulse \/ frequency output or limit monitor 10-year stability\u003cbr\u003e• 0.15 % of URL\u003cbr\u003e\u003cstrong\u003eFlexible configuration options\u003c\/strong\u003e\u003cbr\u003e• Local configuration via keys on LCD indicator\u003cbr\u003e\u003cstrong\u003eTTG (Through-The-Glass) key technology\u003c\/strong\u003e\u003cbr\u003e• Enables quick and easy local configuration without the need to open the cover - even in environments with explosion protection\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eitem\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003evalue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eaccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.075%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003etype\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultivariable Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ebrand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emodel number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e266CSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential Pressure, Absolute Pressure and Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emeasurement principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDynamic Flow Compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eflow measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emeasuring media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eGases, Vapours and Liquids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eapplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential Pressure Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003elevel measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDP Level Measurement with Density Compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003epressure compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure-Dependent Density Compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003etemperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature-Dependent Density Compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eflow compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDischarge Coefficient, Thermal Expansion and Reynolds Number Compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003erange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDown to 0.05 kPa (0.2 inH₂O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003estatic working pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 41 MPa (6000 psi), optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003edisplay technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTTG (Through The Glass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003elocal operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration and Operation without Opening the Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eplugged impulse line detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003etotalizer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Totalizers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ebinary output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse or Frequency Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eelectronics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eExchangeable Electronics with Automatic Configuration Capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eprocess penetrations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eReduced Process Penetrations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003efeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh Precision, Dynamic Flow Compensation, Integrated Totalizers and Plugged Impulse Line Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHART \/ Fieldbus Options Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eapplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFlow Measurement, Level Measurement and Process Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\n\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"magic-7\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56212981317954,"sku":null,"price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Multivariable_transmitter_266CSH.png?v=1789899523","url":"https:\/\/antletstech.com\/es\/products\/abb-differential-pressure-transmitter-266mst-%e5%89%af%e6%9c%ac","provider":"ANTLETS","version":"1.0","type":"link"}