{"product_id":"abb-coriolis-mass-flowmeter-coriolismaster-fcb430","title":"ABB Coriolis mass flowmeter CoriolisMaster FCB430","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv class=\"sfContentBlock\"\u003e\n\u003cp\u003eWith no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe FCB430 series delivers: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to five modular I\/Os\u003cbr\u003e– Multivariable meter design\u003cbr\u003e– Optional plug-in cards\u003cbr\u003e– Automatic firmware update\u003cbr\u003e– Various communication protocols available:\u003cbr\u003e   EthernetIP, Modbus TCP, Web Browser and Profinet\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Ethernet and Ethernet APL\/SPE Connectivity\u003cbr\u003e– Protocols supported: Ethernet IP, Profinet, Modbus TCP\u003cbr\u003e– For remote access to built-in diagnostic monitoring the flowmeter and your process\u003cbr\u003e– Flowmeter verification and configuration over Ethernet minimizing commissioning time\u003cbr\u003e– Built-in webserver, no additional software required for flowmeter configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSmartSensor\u003cbr\u003e– All digital solution\u003cbr\u003e– Installation flexibility\u003cbr\u003e– Meter intelligence located in the sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSensorApplicationMemory\u003cbr\u003e– Maximum data security\u003cbr\u003e– Plug and play electronics replacement \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eABB common look and feel\u003cbr\u003e– Easy Set-up\u003cbr\u003e– Operation through the glass via capacitive keys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eVeriMass on-board verification and diagnostics\u003cbr\u003e– Online preventive maintenance\u003cbr\u003e– Extended maintenance cycles\u003cbr\u003e– Reduced maintenance effort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for 70 °C (158 °F) ambient temperature and high vibrations\u003c\/li\u003e\n\u003cli\u003eEnhanced Coriolis control (ECC) option for advanced measurement for multiphase conditions and other challenging fluids\u003c\/li\u003e\n\u003cli\u003eLower pressure drop\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSelf-draining\u003c\/li\u003e\n\u003cli\u003eGlobal approvals for explosion protection\u003c\/li\u003e\n\u003cli\u003eOIML R117 and MID approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e Benefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eUp to five modular I\/Os \u003c\/strong\u003e\u003cbr\u003e• Optional plug-in cards \u003cbr\u003e• Automatic firmware update \u003cbr\u003e• Integrated solutions for filling operations and concentration \u003cbr\u003emeasurement \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSmartSensor \u003c\/strong\u003e\u003cbr\u003e• All digital solution \u003cbr\u003e• Measuring device intelligence located directly in the sensor \u003cbr\u003e• Lower pressure loss \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eIntegrated VeriMass device verification and diagnosis \u003c\/strong\u003e\u003cbr\u003e• Predictive maintenance in the process \u003cbr\u003e• Extended maintenance cycles \u003cbr\u003e• Reduced maintenance effort \u003cbr\u003e\u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCB430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolisMaster Industrial Coriolis Mass Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolis Mass Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolis Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquids and Gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow, Volume Flow, Density and Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow and Volume Flow: ±0.4% of Rate (Optional ±0.25% \/ ±0.2% of Rate); Density: ±10 g\/l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN15 to DN150 (1\/2 to 6 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN15: 0 to 8,000 kg\/h; DN25: 0 to 35,000 kg\/h; DN50: 0 to 90,000 kg\/h; DN80: 0 to 250,000 kg\/h; DN100: 0 to 520,000 kg\/h; DN150: 0 to 860,000 kg\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModular Inputs \/ Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART; PROFIBUS DP; Modbus RTU (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 to 30 V DC; 100 to 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral Mount or Remote Mount Version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Upstream or Downstream Straight Pipe Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlange DIN EN 1092-1; ASME B16.5; DIN 11851; Tri-Clamp (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel 1.4404 \/ 1.4435 (316L); Hastelloy C (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 to +160 °C (-58 to +320 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to +70 °C (+158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP67 (Integral Mount); IP68 (Remote Sensor, Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVeriMass On-Board Verification and Device Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDensity Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Density Measurement Capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExplosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX \/ IECEx; cFMus (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultivariable Measurement, High Accuracy, Low Pressure Drop, Stable Signal Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRobust Industrial Design, High Accuracy Mass Measurement, Wide Temperature Range, Flexible Communication Options, Reduced Installation Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChemical Processing, Oil \u0026amp; Gas, Energy, Food \u0026amp; Beverage, Pharmaceutical, Filling Systems and General Industrial Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56252056240450,"sku":null,"price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Coriolis_mass_flowmeter_CoriolisMaster_FCB430_3.png?v=1790221266","url":"https:\/\/antletstech.com\/es\/products\/abb-coriolis-mass-flowmeter-coriolismaster-fcb430","provider":"ANTLETS","version":"1.0","type":"link"}