Overview
Endress+Hauser Proline Promag P100 Electromagnetic Flowmeter, it is a flowmeter for highest medium temperatures with an ultra-compact transmitter.
Specs at a glance
Max. measurement error Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s Measuring range 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) Medium temperature range Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)
Application
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.
* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
* Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
* Nominal diameter: max. DN 600 (24")
* All common Ex approvals
* Liner made of PTFE or PFA
* Robust, ultra-compact transmitter housing
* Local display available
Benefits
* Versatile applications – wide variety of wetted materials
* Energy-saving flow measurement – no pressure loss due to cross-section constriction
* Maintenance-free – no moving parts
* Space-saving transmitter – full functionality on the smallest footprint
* Time-saving local operation without additional software and hardware – integrated web server
* Integrated verification – Heartbeat Technology
Specification
Measuring principle | Electromagnetic |
Product headline | The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
Sensor features | Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. |
Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Local display available. |
Nominal diameter range | DN 15 to 600 (½ to 24") |
Wetted materials | Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803) |
Measured variables | Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity |
Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s |
Measuring range | 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) |
Max. process pressure | PN 40, Class 300, 20K |
Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | DN 15 to 300 (½ to 12"): AlSi10Mg, coated DN 350 to 600 (14 to 24"): Carbon steel with protective varnish |
Transmitter housing material | AlSi10Mg, coated |
Degree of protection | IP66/67, type 4X enclosure |
Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET |
Power supply | DC 20 to 30 V |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO |
Other approvals and certificates | |
Product safety | CE, C-Tick |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
Pressure approvals and certificates | PED, CRN |
Material certificates | 3.1 material |
Hygienic approvals and certificates | Drinking water approval: ACS, NSF 61, WRAS |
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.