Endress+Hauser Capacitance Level measurement Liquicap FMI52

: In stock

: Level Measurement

: Endress+Hauser

Precio habitual Oferta

Overview  For continuous level and interface measurement in liquids - for large measuring ranges. Specs at a glance * Accuracy repeatablity 0,1% * Process temperature -80°C...200°C -112°F...392°F *...


Overview 

For continuous level and interface measurement in liquids - for large measuring ranges.
Specs at a glance
* Accuracy
repeatablity 0,1%
* Process temperature
-80°C...200°C
-112°F...392°F
* Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vaccum ... 1450 psi)
* Max. measurement distance
0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
* Main wetted parts
Insulation material: FEP,PFA, 316L

Application

Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks,build-up forming media and extremely high temperatures - especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.

Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
* Process connections: Flanges and threads
* Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
* Measuring range: 0.42 to 10.0m (1.38 to 33ft)
* Temperature: -80 to +200°C (-112 to +392°F)
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals

Benefits

* Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
* Reliable and universal application thanks to wide range of certificates and approvals
* No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
* Material in contact with the process made of corrosion-resistant material
* Menu-guided local configuration via plain text display (optional)
* Two-stage overvoltage protection

Specification 

item
value
Grade
Industrial
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Liquicap FMI52
Mode
Capacitance Level Measurement
Measuring Principle
Capacitive
Characteristic / Application
Fully insulated rope probe, for standard and extreme process conditions (temperature, pressure)
Interface Measurement
Interfaces liquid / liquid also with emulsion layers
Specialities
Inactive length
Factory calibrated
short response time by change of value
Supply / Communication
12-36V DC HART
PFM
Accuracy
repeatablity 0,1%
Linearity Error For Conductive Liquids
<0,25%
Ambient Temperature
-50°C ... 70°C
(-58°F ... 158°F)
Process Temperature
-80°C...200°C
-112°F...392°F
Process Pressure / Max. Overpressure Limit
Vacuum ... 100 bar
(Vaccum ... 1450 psi)
Main Wetted Parts
Insulation material: FEP,PFA
316L
Process Connection
G 3/4, G 1, G1 1/2 /NPT 3/4", NPT 1, NPT1 1/2"
Flange from DN25.../ASME 1".../JIS...
Process Connection Hygienic
Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor Length
Total length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. Measurement Distance
0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
Communication
4...20mA HART
PFM
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety Approvals
SIL
Design Approvals
EN 10204-3.1
NACE MR0175
Hygienic Approvals
EHEDG
Marine Approval
GL/ ABS/ DNV
Options
Separate housing
gas-tight probe seal
Application Limits
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating


please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.