Overview
A level switch for hot and pumpable liquids.
Specs at a glance
* Process temperature
-60 °C...+280 °C
(-76 °F...+536 °F)
* Process pressure / max. overpressure limit
Vacuum...100 bar
Vacuum...1450 psi
* Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional)
-60 °C...+280 °C
(-76 °F...+536 °F)
* Process pressure / max. overpressure limit
Vacuum...100 bar
Vacuum...1450 psi
* Min. density of medium
0.5 g/cm³
(0.4 g/cm³ optional)
Field of application
Liquiphant FTL64 has a strong focus on high temperature applications and simplicity with easy proof testing, reliability and safety (SIL) with compliance to IEC 61508, API 2350 and WHG. The vibronic device is determined for a safe and active measuring technology in applications with high temperatures and want a reliable and proven point level detection for tank overfill protection and pump dry run protection. The FTL64 is easy to use, has a digital connection and gives a real-time data at hand.
Point level switch with extension tube for pumpable liquids
* Process temperature: -60 °C to +280°C (PFA coated: up to 230°C)
* Process pressure: -1 to +100bar (PFA coated: up to 40bar)
* Ambient temperature: -60 to +70°C
* Viscosity up to 10,000mm2/s (cSt)
* Optional PFA coating for aggressive media
* Process connections: threads, flanges and hygienic process connection (Tri-Clamp)
* International explosion protection certificates, overfill protection WHG, SIL, marine approvals
Point level switch with extension tube for pumpable liquids
* Process temperature: -60 °C to +280°C (PFA coated: up to 230°C)
* Process pressure: -1 to +100bar (PFA coated: up to 40bar)
* Ambient temperature: -60 to +70°C
* Viscosity up to 10,000mm2/s (cSt)
* Optional PFA coating for aggressive media
* Process connections: threads, flanges and hygienic process connection (Tri-Clamp)
* International explosion protection certificates, overfill protection WHG, SIL, marine approvals
Benefits
* Universal measuring principle for limit detection – proven vibronic technology
* Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)
* Periodic proof testing is quickly and simple organized with guided wizards via the SmartBlue-App or via a test button or
magnetic pin from outside. Via digital communication you can initiate the device for a fast and easy testing of the safety loop.
* Heartbeat Technology allows safe, continuous diagnostics and a simple verification, without process interruption
* Centralized asset management with easy online access to all device information thanks to digital communication
* Second line of defense to protect the environment
* Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)
* Periodic proof testing is quickly and simple organized with guided wizards via the SmartBlue-App or via a test button or
magnetic pin from outside. Via digital communication you can initiate the device for a fast and easy testing of the safety loop.
* Heartbeat Technology allows safe, continuous diagnostics and a simple verification, without process interruption
* Centralized asset management with easy online access to all device information thanks to digital communication
* Second line of defense to protect the environment
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Liquiphant FTL64
|
Material
|
316L
Alloy |
Mode
|
Point Level Switch
|
Measuring Principle
|
Vibration Liquids
|
Characteristic / Application
|
Compact vibronic device for high pressure and high temperature applications,
Optional extension tube up to 6 m (19.7 ft), Modular housing concept, Wide range of certificates |
Specialities
|
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Second line of defense, Temperature spacer for high process temperature, Plug and play functionalities |
Supply / Communication
|
19...253V AC / 2-wire,
10...55V / DC-PNP 3-wire, 9...20V DC with relay DPDT, 19...253V AC or 19...55V DC with relay DPDT, 2-wire NAMUR, 2-wire PFM, 4-20mA HART |
Ambient Temperature
|
-60 °C...+70 °C
(-76 °F...+158 °F) |
Process Temperature
|
-60 °C...+280 °C
(-76 °F...+536 °F) |
Process Pressure / Max. Overpressure Limit
|
Vacuum...100 bar
Vacuum...1450 psi |
Min. Density Of Medium
|
0.5g/cm³(0.4g/cm³ optional)
|
Main Wetted Parts
|
316L
Alloy |
Process Connection
|
Threads:
3/4", 1" Flanges: DN25...DN100 ASME 1"...4" JIS 50A |
Process Connection Hygienic
|
FDA conform with PFA (Edlon)
|
Sensor Length
|
up to 6 m (19.7 ft)
|
Communication
|
2-wire direct load
HART DC-PNP 3-wire Relays NAMUR PFM Bluetooth® wireless technology |
Certificates / Approvals
|
ATEX, IEC Ex, NEPSI, EAC Ex, KC, JPN Ex, INMETRO, UK Ex
|
Safety Approvals
|
Overfill protection WHG
SIL2/ SIL 3 according to IEC 61508 |
Design Approvals
|
EN 10204-3.1
NACE MR0175, MR0103 ASME B31.3 Process Piping AD2000 CRN |
Marine Approval
|
ABS/ LR/ BV/ DNV
|
Options
|
Ambient temperature down to -60 °C (-76 °F),
Heavy duty stainless steel housing, Coating PFA (conductive) |
Components
|
FTL325P Interface PFM
FTL325N Interface NAMUR |