Overview
Toroidal conductivity measuring system for hygienic applicationsApplication
Smartec CLD18 is the cost-effective solution for all applications in beverage plants where small tubes are used and where the toroidal measurement is used as a switch function. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a hygienic design that protects your products and processes from contamination. Smartec CLD18 ensures the Overall Equipment Effectiveness (OEE) of your plant thanks to fast and reliable CIP and optional IO-Link protocol.
The hygienic Smartec CLD18 measures toroidal conductivity in beverage applications:
-
Control of CIP processes in the return channel
-
Concentration control in remaking of CIP cleaning agents
-
Product monitoring in pipe systems, bottling plants
-
Beer - Push water interphase
-
Beer - Water cut for brewing lines
-
Leakage monitoring
It features the following protocols and interfaces:
-
0/4...20mA
-
IO-Link (optional)
Condumax CLS21 measures conductivity in all process and environmental applications, such as:
-
Potable water treatment
-
Desalination plants
-
Industrial water treatment
-
River/lake monitoring
-
Phase separation in medium conductivities (e.g. milk/water)
With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.
Benefits
-
Unique hygienic design avoids contamination
-
3-A approval
-
Compliant with EG 2023/2006 and 1935/2004
-
Suitable for cleaning-in-place (CIP)
-
Smart and easy integration into your plant infrastructure thanks to optional IO-Link protocol
-
Compact design permits installation in small tubes without restricting the flow
Specification
|
item
|
value
|
|
Grade
|
Industrial
|
|
Warranty
|
1 Year
|
|
Customized support
|
OEM
|
|
Place of Origin
|
Germany
|
|
Brand Name
|
Endress+Hauser
|
|
Model Number
|
CLD18 |
|
Measuring Principle
|
Inductive
|
|
Application |
Specifically intended for use in beverage industry applications and especially suitable for: Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring |
|
Measuring range |
200 µS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm |
|
Measuring principle |
Inductive conductivity measurement
|
|
Design |
Hygienic design with FDA certified virgin PEEK
|
|
Material |
Sensor: PEEK Process connection 1.4435 (316L) Seal: EPDM |
|
Process temperature |
-10 °C to 110 °C (14 °F to 230 °F) Sterilization: max. 130 °C at 6 bar abs up to 60 min (Max. 266 °F at 87 psi up to 60 min) |
|
Process pressure
|
13 bar abs up to 50 °C (188.5 psi up to 122 °F) 7.75 bar abs at 110 °C (112 psi at 230 °F) 6.0 bar abs at 130 °C for max. 60 minutes (87 psi at 266 °F for max. 60 minutes) |
|
Temperature sensor |
Pt 1000 (class B) |
|
Connection |
Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2" ISO 2852, SMS-2", Varivent N DN 40-125 Thread G1 1/2 SS, G1 1/2 PVC , Union nut 2 1/4 Inch PVC |
|
Ingress protection |
IP69 |
Output / communication |
0/4...20mA |
Certificates, declarations and approvals |
Inspection certificate 3.1, EN10204 |
Worldwide Shipping
We are proud to offer worldwide shipping to meet your needs, no matter where you are located.
How We Ship
We normally ship via DHL, UPS, or FedEx for fast and trackable delivery.
Flexible Shipping Options
Depending on your order size and timeline, we also support Air Freight and Sea Freight options.
Trade Terms
We can arrange shipments under DAP (Delivered at Place) or DDP (Delivered Duty Paid). Just let us know your preference.
Why Choose Us
With years of experience and long-term cooperation with reliable freight forwarders, we ensure competitive rates and smooth customs clearance.