Overview
-40 °C ... 150 °C
(-40 °F ... 302 °F)
* Process pressure / max. overpressure limit
Vacuum ... 40 bar
(Vacuum ... 580 psi)
* Min. density of medium
>0,7g/cm³
(>0,5g/cm³ optional)
Field of application
Compact:
- Smallest vibronic sensor in the market
Safe:
- Continuous self-monitoring
- Reliable switching independent of media properties
Easy:
- No calibration
- Plug & play
-IO-Link connectivity
Point level switch in compact hygienic design with stainless steel housing for the food industry.
* Process connections: Threads, hygienic process connections, M24 process adapter
* Temperature: -40 to +150°C (-40 to +302°F)
* Pressure: -1 to +40bar (-14.5 to +580psi)
* Surface roughness: 0.76µm or 1.5µm
* Overfill protection and leakage detection WHG, hygienic certificates, final inspection report
Benefits
IO-Link reduces costs and complexity due to easy configuration of the devices via engineering tools
* CIP and SIP cleanability ensured - up to protection class IP69k
* Designed according to highest requirements to quality and environmental sustainability, the self-monitoring Liquiphant offers safe switching also in case of power supply loss
* Independent of changing media properties an accurate switching point is offered
* A real plug & play sensor is offered without any need for adjustment even with changing media. Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubbles
* No calibration is required, no specific know-how or tools (e.g. software) necessary
* Robust design made of stainless steel (316L) assures highest durability - no mechanically moved parts, free of maintenance
Specification
|
item
|
value
|
|
Grade
|
Industrial
|
|
Warranty
|
1 Year
|
|
Customized support
|
OEM
|
|
Place of Origin
|
Germany
|
|
Brand Name
|
Endress+Hauser
|
|
Model Number
|
Liquiphant FTL51B
|
|
Material
|
316L
|
|
Mode
|
Point Level Switch
|
|
Measuring Principle
|
Vibration Liquids
|
|
Characteristic / Application
|
Point level switch for liquids
in the food sector |
|
Supply / Communication
|
20 ... 253V AC/DC, 2-wire
10 ... 30V DC-PNP, 3-wire |
|
Ambient Temperature
|
-40 °C ... 70 °C
(-40 °F ... 158 °F) |
|
Process Temperature
|
-40 °C ... 150 °C
(-40 °F ... 302 °F) |
|
Process Pressure / Max. Overpressure Limit
|
Vacuum ... 40 bar
(Vacuum ... 580 psi) |
|
Min. Density Of Medium
|
>0,7g/cm³
(>0,5g/cm³ optional) |
|
Main Wetted Parts
|
316L
|
|
Process Connection
|
Threads:
G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1 |
|
Process Connection Hygienic
|
Flush mount by use of weld in adapter
DIN11851 Tri-Clamp |
|
Communication
|
AC/DC, DC-PNP, IO-Link
|
|
Certificates / Approvals
|
CSA C/US, EAC
|
|
Safety Approvals
|
Overfill protection WHG
Leakage |
|
Design Approvals
|
EN 10204-3.1
|
|
Hygienic Approval
|
3A, EHEDG
|
|
Options
|
Switching delay
Cleaned from oil+grease, Surface finish measurement |
Worldwide Shipping
We are proud to offer worldwide shipping to meet your needs, no matter where you are located.
How We Ship
We normally ship via DHL, UPS, or FedEx for fast and trackable delivery.
Flexible Shipping Options
Depending on your order size and timeline, we also support Air Freight and Sea Freight options.
Trade Terms
We can arrange shipments under DAP (Delivered at Place) or DDP (Delivered Duty Paid). Just let us know your preference.
Why Choose Us
With years of experience and long-term cooperation with reliable freight forwarders, we ensure competitive rates and smooth customs clearance.