Endress+Hauser 8A3C Proline Promass A300 Coriolis Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Precio habitual Oferta

OverviewEndress+Hauser Proline Promass A300 Coriolis Flowmeter is an accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter.Specs at a glance* Max. measurement errorMass flow...

Overview

Endress+Hauser Proline Promass A300 Coriolis Flowmeter is an accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter.

Specs at a glance

* Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 450 kg/h (0 to 16.54 lb/min)
* Medium temperature range
-50 to 205 °C (-58 to 401 °F)
* Max. process pressure
430.9 bar (6250 psi)
* Wetted materials
Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22

Application

Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its compact transmitter Promass A 300 offers high flexibility in terms of operation and system integration: access from one side, remote display, improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Suitable for applications with smallest flow quantities in all industries
Device properties
* Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
* Process pressure up to 430.9 bar (6250 psi)
* Medium temperature up to +205 °C (+401 °F)
* Compact dual-compartment housing with up to 3 I/Os
* Backlit display with touch control and WLAN access
* Remote display available 
 

Benefits

* Space-saving installation – compact, lightweight sensor
* Highest product quality – self-drainable measuring tube in all line sizes
* Optimum process safety – resistant to corrosive ambient conditions and internal clogging
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology 
 

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Swaziland
Brand Name Endress+Hauser
Model Number Proline Promass A300
Type Coriolis meters, Coriolis flowmeter
Measuring Principle Coriolis
Product Headline Accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter. 
Suitable for applications with smallest flow quantities in all industries.
Sensor Features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all 
line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging. 
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 
°F).
Transmitter Features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and 
variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. 
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal Diameter Range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted Materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured Variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. Measurement Error Mass flow (liquid): ±0.1 % 
Volume flow (liquid): ±0.1 % 
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring Range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. Process Pressure 430.9 bar (6250 psi)
Medium Temperature Range -50 to 205 °C (-58 to 401 °F)
Ambient Temperature Range -40 to 60 °C (-40 to +140 °F)
Sensor Housing Material Stainless steel, 1.4404 (316L)
Transmitter Housing Material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree Of Protection Compact version: IP66/67, type 4X enclosure. 
External WLAN antenna: IP67 
IP69
Display/Operation 4-line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible 
Remote display available
Outputs 3 outputs: 
4-20 mA HART (active/passive) 
4-20 mA WirelessHART 
4-20 mA (active/passive) 
Pulse/frequency/switch output (active/passive) 
Double pulse output (active/passive) 
Relay output
Inputs Status input 
4-20 mA input
Digital Communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power Supply DC 24 V 
AC 100 to 230 V 
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex
Product Safety CE, C-TICK
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation)
Hygienic Approvals And Certificates 3-A, cGMP
Pressure Approvals And Certificates CRN
Material Certificates 3.1 material 
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,