Overview
Endress+Hauser Proline Promag P100 Electromagnetic Flowmeter, it is a flowmeter for highest medium temperatures with an ultra-compact transmitter.
Specs at a glance
Max. measurement error Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s Measuring range 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) Medium temperature range Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)
Application
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.
* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
* Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
* Nominal diameter: max. DN 600 (24")
* All common Ex approvals
* Liner made of PTFE or PFA
* Robust, ultra-compact transmitter housing
* Local display available
Benefits
* Versatile applications – wide variety of wetted materials
* Energy-saving flow measurement – no pressure loss due to cross-section constriction
* Maintenance-free – no moving parts
* Space-saving transmitter – full functionality on the smallest footprint
* Time-saving local operation without additional software and hardware – integrated web server
* Integrated verification – Heartbeat Technology
Specification
| Measuring principle | Electromagnetic |
| Product headline | The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
| Sensor features | Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA. |
| Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Local display available. |
| Nominal diameter range | DN 15 to 600 (½ to 24") |
| Wetted materials | Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803) |
| Measured variables | Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s |
| Measuring range | 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
| Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | DN 15 to 300 (½ to 12"): AlSi10Mg, coated DN 350 to 600 (14 to 24"): Carbon steel with protective varnish |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO |
| Other approvals and certificates | |
| Product safety | CE, C-Tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | Drinking water approval: ACS, NSF 61, WRAS |
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
English
Arabic
Chat with Us