Overview
Endress+Hauser Proline t-mass B150 thermal mass flowmeter is a flowmeter for cost-effective measurement and easy monitoring of utility gases.
Specs at a glance
* Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
* Measuring range
20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
* Medium temperature range
–40 to +100 °C (–40 to +212 °F)
* Max. process pressure
20 bar g (290 psi g)
* Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
Field of application
The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
Device properties
* Insertion version for nominal diameter DN 80 to 1500 (3 to 60")
* Installation and removal of sensor without process interruption
* Easy installation
* Device in compact version with DC 24 V power supply
* 4-20 mA HART, pulse/frequency/switch output
* Compact and robust transmitter
Benefits
* Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts
* Optimal process monitoring – easy measurement even at low pressures and flow velocities
* Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
* Reliable flow trending – multivariable measurement
* Fast and efficient commissioning – guided operating menus
* High plant availability – self-diagnostics and error monitoring
* Automatic recovery of data for servicing
Specification
| Measuring Principle | Thermal |
| Product Headline | The flowmeter for cost-effective measurement and easy monitoring of utility gases. Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts. |
| Sensor Features | Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost‐effective measurement – easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion version for nominal diameter DN 80 to 1500 (3 to 60"). Installation and removal of sensor without process interruption. Easy installation. |
| Transmitter Features | Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter. |
| Nominal Diameter Range | DN 80 to 1500 (3 to 60") |
| Wetted Materials | Transducer: 1.4404 (316L) Insertion tube: 1.4404 (316L); 1.4435 (316L) Connection: Compression fitting: 1.4404 (316L) Sealing ring: EPDM; HNBR; 1.4401 (316) Clamping ring: PEEK 450G |
| Measured Variables | Mass flow, temperature, corrected volume flow, FAD volume flow |
| Max. Measurement Error | 3 % o.r. 4 % o.r. 5 % o.f.s. (depending on chosen option of ordering feature "Calibration flow") |
| Measuring Range | 20 to 720 000 kg/h (45 to 1 587 600 lb/h) 20 to 1 080 000 kg/h (45 to 2 381 400 lb/h) (for air, depending on chosen option of ordering feature "Calibration flow") |
| Max. Process Pressure | 20 bar g (290 psi g) |
| Medium Temperature Range | –40 to +100 °C (–40 to +212 °F) |
| Ambient Temperature Range | –40 to +60 °C (–40 to +140 °F) |
| Transmitter Housing Material | AlSi10Mg, coated |
| Degree Of Protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line display with push Buttons Configuration via local display and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital Communication | HART |
| Power Supply | DC 18 to 30 V |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus |
| Metrological Approvals And Certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure Approvals And Certificates | CRN |