Overview
Endress+Hauser Proline t-mass A150 thermal mass flowmeter is a flowmeter for cost-effective measurement and easy monitoring of utility gases.
Specs at a glance
* Max. measurement error
3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")
* Measuring range
0.5 to 910 kg/h (1.1 to 2002 lb/h)
0.5 to 1365 kg/h (1.1 to 3003 lb/h)
(for air, depending on chosen option of ordering feature "Calibration flow")
* Medium temperature range
–40 to +100 °C (–40 to +212 °F)
* Max. process pressure
PN 40, Class 300
* Wetted materials
Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L)
Measuring tube: 1.4404 (316L); 1.4435 (316L)
Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L)
Field of application
The t-mass A 150 inline device is specially designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at subetering applications. its 4-wire technology is contained within a rugged compact aluminum housing. It is orderable either with display or as a blind version. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Suitable for air, nitrogen, carbon dioxide and argon in small line sizes.
Device properties
* Inline version: nominal diameter DN 15 to 50 (1/2 to 2")
* Process pressure up to PN 40, Class 300
* A variety of process connections available
* Device in compact version with DC 24 V power supply
* 4-20 mA HART, pulse/frequency/switch output
* Compact and robust transmitter
Benefits
* Suitable for air, nitrogen, carbon dioxide and argon in small line sizes
* Optimal process monitoring – easy measurement even at low pressures and flow velocities
* Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
* Reliable flow trending – multivariable measurement
* Fast and efficient commissioning – guided operating menus
* High plant availability – self-diagnostics and error monitoring
* Automatic recovery of data for servicing
Specification
| Measuring Principle | Thermal |
| Product Headline | The flowmeter for cost-effective measurement and easy monitoring of utility gases. Suitable for air, nitrogen, carbon dioxide and argon in small line sizes. |
| Sensor Features | Optimal process monitoring – easy measurement even at low pressures and flow velocities. Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free. Reliable flow trending – multivariable measurement. Inline version: DN 15 to 50 (½ to 2"). Process pressure up to PN 40, Class 300. A variety of process connections available. |
| Transmitter Features | Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4-20 mA HART, pulse/frequency/switch output. Compact and robust transmitter. |
| Nominal Diameter Range | DN 15 to 50 (½ to 2") |
| Wetted Materials | Transducer: 1.4404 (316L) Insertion tube: 1.4404 (316L) Measuring tube: 1.4404 (316L); 1.4435 (316L) Connection: 1.4404 (F316/F316L); 1.4404 (316L); 1.4435 (316L) |
| Measured Variables | Mass flow, temperature, corrected volume flow, FAD volume flow |
| Max. Measurement Error | 3 % o.r. 4 % o.r. 5 % o.f.s. (depending on chosen option of ordering feature "Calibration flow") |
| Measuring Range | 0.5 to 910 kg/h (1.1 to 2002 lb/h) 0.5 to 1365 kg/h (1.1 to 3003 lb/h) (for air, depending on chosen option of ordering feature "Calibration flow") |
| Max. Process Pressure | PN 40, Class 300 |
| Medium Temperature Range | –40 to +100 °C (–40 to +212 °F) |
| Ambient Temperature Range | –40 to +60 °C (–40 to +140 °F) |
| Transmitter Housing Material | AlSi10Mg, coated |
| Degree Of Protection | IP66/67, type 4X enclosure |
| Display/Operation | 4‐line display with push Buttons Configuration via local display and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital Communication | HART |
| Power Supply | DC 18 to 30 V |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus |
| Metrological Approvals And Certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure Approvals And Certificates | PED, CRN |