Endress+Hauser iTHERM TM401 Modular RTD Thermometer - basic Technology

: In stock

: Temperature Meaurement

: Endress+Hauser

Precio habitual Oferta

Overview For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries. Specs at a glance Accuracyclass A acc. to IEC 60751Response timedepending on...


Overview

For standard hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.

Specs at a glance

Accuracy
class A acc. to IEC 60751
Response time
depending on configuration
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. immersion length on request
up to 400 mm (15,75")


Field of application


This iTHERM thermometer has been designed to meet the basic requirements of the Food & Beverages and Life Sciences industries at the best price. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. The device uses basic technology with features such as a fixed, non-replaceable insert, a wide range of process connections and international certification at an excellent value for money.

Benefits


* Excellent value for money and fast delivery
* User-friendly and reliable from product selection to maintenance
* International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
* Wide range of process connections
* Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
* Measuring range: –50 to +200 °C (–8 to +392 °F)
* Pressure range up to 50 bar (725 psi)
* Protection class: up to IP69K
* Can be used in non-hazardous areas

Specification


Brand Name
ENDRESS+HAUSER
Model Number
TM401
Theory
Temperature Transmitter
Material
316L
Type
Temperature Transmitter
Measuring range
-50 to +200 °C (-8 to +392 °F)
Pressure range
up to 50 bar (725 psi)
Protection class
up to IP69K
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Operating temperature range
PT100: -50 °C ... 200 °C (-58 °F ... 392 °F)
Max. immersion length on request
up to 400 mm (15,75")
Measuring principle
Resistance Temperature Detector
Characteristic / Application
metric style
hygienic applications
aseptic applications
hygienic process connections
with neck
Thermowell / protection tube
without (not intended to use with thermowell)
Insert / probe
without exchangeable insert
Outer diameter protection tube / Insert
6,0 mm (0,24")
8,0 mm (0,31")
Max. immersion length on request
up to 400 mm (15,75")
Material protection tube/ thermowell
316L
Process connection
compression fitting
triclamp
microclamp
clamp connections acc. to ISO2852
Ingold
G3/4" Liquiphant
G1" Liquiphant
Varivent
SMS 1147
screwed pipe joint acc. to DIN 11851
Tip shape
straight
reduced
Surface roughness Ra
0,76 μm (30 μin)
0,38 μm (15 μin)
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Accuracy
class A acc. to IEC 60751
Integration head transmitter
yes (4 ... 20 mA, HART)
Certification
SIL (transmitter only)


please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.