{"product_id":"abb-thermal-mass-flowmeter-sensymaster-fmt430","title":"ABB Thermal mass flowmeter SensyMaster FMT430","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 74, 165);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eThe ABB SensyMaster FMT430 is thermal mass flowmeters designed for precise and dynamic direct mass flow measurement of gases and gas mixtures in industrial applications. Based on the hot-film anemometer measuring principle, these instruments provide direct gas mass flow measurement without requiring additional pressure and temperature compensation when the gas composition is known and constant.\u003c\/p\u003e\n\u003cp\u003eThe SensyMaster series combines high-quality thermal sensor elements with ABB's digital electronic platform, offering reliable measurement performance, flexible application configuration, and integrated diagnostic functions.\u003c\/p\u003e\n\u003cp\u003eFMT430 is designed for standard gas flow measurement applications, while FMT450 provides enhanced accuracy and extended application capabilities, including optional process gas calibration and filling application software.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePrecise and dynamic direct mass flow measurement of gases for industrial standard applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-grade thermal sensor elements\u003cbr\u003e– superior long-term stability\u003cbr\u003e– effective sensor element protection frame with flow conditioning properties\u003c\/li\u003e\n\u003cli\u003eSmartSensor solution\u003cbr\u003e– Meter intelligence located at the sensor\u003cbr\u003e– all digital solution\u003cbr\u003e– reduced wiring costs with industry standard connection cables\u003cbr\u003e– long cable distances are possible\u003c\/li\u003e\n\u003cli\u003eSensorApplicationMemory\u003cbr\u003e– Plug and play electronics replacement\u003cbr\u003e– Redundant data storage for maximum data security\u003c\/li\u003e\n\u003cli\u003eABB common electronic concept\u003cbr\u003e– Through-the-glass operation\u003cbr\u003e– Modular I\/O Concept\u003cbr\u003e– Multiple 32-bit processor structure\u003cbr\u003e– full digital heating circuit control\u003cbr\u003e– dynamic temperature compensation\u003c\/li\u003e\n\u003cli\u003eApplicationSelector\u003cbr\u003e– Adaption of the characteristic application parameters on site\u003cbr\u003e– choice between up to two applications (FMT430)\u003cbr\u003e– choice between up to eight applications (FMT450)\u003cbr\u003e– setup new applications without the need for recalibration (FMT450)\u003c\/li\u003e\n\u003cli\u003eVeriMass onboard verification and diagnostics\u003cbr\u003e– Fingerprint based SensorCheck to verify the integrity of the thermal sensor elements\u003cbr\u003e– continuous health check of the meter\u003cbr\u003e– parameter plausibility check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(11, 70, 157);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Mass Flow Measurement:\u003c\/strong\u003e Thermal measurement technology enables direct measurement of gas mass flow without additional pressure and temperature compensation under specified gas conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Thermal Sensor Technology:\u003c\/strong\u003e High-quality sensor elements with ceramic carrier material and protective frames support long-term stability and repeatable measurement performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Application Configuration:\u003c\/strong\u003e ApplicationSelector supports up to 2 applications with FMT430 and up to 8 applications with FMT450.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Communication:\u003c\/strong\u003e Standard HART communication with optional Modbus RTU and PROFIBUS DP interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular I\/O Design:\u003c\/strong\u003e Optional plug-in cards allow additional current outputs, digital outputs, digital inputs, and communication interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Internal device monitoring and optional VeriMass SensorCheck help monitor sensor element integrity and identify possible deposits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Installation:\u003c\/strong\u003e Integral and remote mounting designs are available, with different pipe components and sensor connection options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced FMT450 Functions:\u003c\/strong\u003e Optional process gas calibration, extended measuring range, and FillMass filling application functionality support more demanding applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(10, 71, 164);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFMT430 (air): ±1.2% of measured value in the range of 10–100% of the standard measuring range; ±0.12% of QmaxDN in the range of 0–10%.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eThermal Mass Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eBrand Name\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eModel Number\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSensyMaster FMT430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eMeasurement Type\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDirect Gas Mass Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eMeasurement Media\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAir, nitrogen, oxygen, carbon dioxide, methane, hydrogen, natural gas, biogas, helium, argon, propane, ethane, ethylene, butane, ammonia, and other gases subject to availability and application requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eLevel Measurement\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot Applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4–20 mA active or passive current output; two passive digital outputs configurable as pulse, frequency, or binary outputs. Additional outputs and inputs available via optional plug-in cards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Protocols\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHART 7.1 standard; optional Modbus RTU and PROFIBUS DP via plug-in cards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptional integrated LCD indicator with push buttons and through-the-glass operation; available configuration without display.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Technology\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLCD indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eLocal Operation\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMenu-guided parameterization using four buttons through the front glass, with Easy Setup function for commissioning (with optional LCD indicator).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eElectronics\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eABB digital electronic platform with modular input\/output plug-in cards, HART communication, dynamic temperature compensation, and SensorApplicationMemory.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eTerminal Block\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower supply terminals L\/N for AC or 1+\/2− for DC; current output terminals Uco\/32 or 31\/32; digital output terminals 41\/42 and 51\/52; optional plug-in card terminals V1\/V2 and V3\/V4.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eTurndown Ratio\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMeasuring range dynamics up to 1:100, depending on application and configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eSafety Certification\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eATEX \/ IECEx and cFMus explosion protection options. SIL 2 certification available as an ordering option (CS).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegral or remote mounting design; single-compartment or dual-compartment transmitter housing.\u003cbr\u003eFMT430: ApplicationSelector for up to 2 applications.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eFeatures\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSmartSensor technology, SensorApplicationMemory, dynamic temperature compensation, Easy Setup, and internal device diagnostics.\u003cbr\u003eOptional VeriMass SensorCheck for sensor element integrity verification.\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eApplications\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGas flow measurement in chemical and process industries, compressed air balancing, gas burner control, biogas and digester gas measurement, sewage treatment plant aeration, air separation, and hydrogen measurement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eProcess Connection\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFlange DN 25 according to EN 1092-1, PN 40; male thread according to DIN 11851, PN 16; NPT 1 in male-thread compression fitting, PN 20. Different pipe components are available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eElectrical Connection\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eM20 × 1.5 or 1\/2 in NPT cable gland options. Remote mounting uses a separate sensor signal cable, with a maximum cable length of 100 m (328 ft).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eWetted Materials\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSensor: stainless steel 1.4404 (AISI 316L); sensor element: ceramic. Sensor connection gasket options include Viton, Kalrez, EPDM, FKM, and HNBR, depending on design and application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #ddd;\"\u003eHousing\u003c\/th\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCast aluminum, painted, RAL 9002. Single-compartment or dual-compartment housing options. Selected remote sensor housing configurations are also available in stainless steel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68315639185730,"sku":null,"price":6000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Thermal_mass_flowmeter_SensyMaster_FMT430.png?v=1795492185","url":"https:\/\/antletstech.com\/ar\/products\/abb-thermal-mass-flowmeter-sensymaster-fmt430","provider":"ANTLETS","version":"1.0","type":"link"}