{"product_id":"abb-differential-pressure-transmitter-with-diaphragm-seal-pdd300","title":"ABB Differential pressure transmitter with diaphragm seal PDD300","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(11, 72, 162);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003eThe ABB PDD300 is an all-rounder differential pressure transmitter designed for use with S26 diaphragm seals. It is suitable for measuring liquid, gas and steam pressure, as well as liquid level in open tanks.\u003c\/p\u003e\n\u003cp\u003eCombining ABB transmitter technology with the S26 diaphragm seal system, the PDD300 provides flexible measurement solutions for applications where the process medium needs to be isolated from the transmitter. The diaphragm seals can be directly or remotely mounted, depending on the installation requirements.\u003c\/p\u003e\n\u003cp\u003eThe S26 diaphragm seal system features an all-welded construction designed to reduce leakage risks during operation. A wide selection of diaphragm materials, seal types, filling fluids and process connections supports different industrial process requirements.\u003c\/p\u003e\n\u003cp\u003eThe PDD300 offers 4–20 mA output with HART communication, Digital Advanced Diagnostics and optional local LCD operation. Its available configurations include H-Shield diaphragm material for applications requiring additional resistance to hydrogen permeation.\u003c\/p\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 78, 175);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible measurement applications:\u003c\/strong\u003e Suitable for liquid, gas and steam pressure measurement, as well as liquid level measurement in open tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess isolation:\u003c\/strong\u003e S26 diaphragm seals isolate the transmitter from the process medium, making the system suitable for applications involving viscous, corrosive, hazardous or solids-containing media.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-welded diaphragm seal construction:\u003c\/strong\u003e Designed to reduce leakage risks and support reliable operation under demanding process conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible installation:\u003c\/strong\u003e Supports direct-mounted and remote diaphragm seal configurations, depending on the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide material selection:\u003c\/strong\u003e Available diaphragm materials include AISI 316L stainless steel, Hastelloy C-276, gold-plated AISI 316L and H-Shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital communication:\u003c\/strong\u003e 4–20 mA output with HART communication and Easy Set up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal operation:\u003c\/strong\u003e Optional LCD display and keypad support local configuration and operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced diagnostics:\u003c\/strong\u003e Includes Digital Advanced Diagnostics features for improved instrument monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(15, 80, 179);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eBase accuracy: 0.05% of calibrated span according to ordering information. Actual accuracy depends on the selected sensor, diaphragm seal configuration and turndown ratio. Refer to the accuracy details below.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eDifferential Pressure Transmitter with S26 Diaphragm Seal(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand Name\u003c\/th\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003ePDD300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Type\u003c\/th\u003e\n\u003ctd\u003eDifferential Pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Media\u003c\/th\u003e\n\u003ctd\u003eLiquid, gas and steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel Measurement\u003c\/th\u003e\n\u003ctd\u003eLiquid level measurement in open tanks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpan Limits\u003c\/th\u003e\n\u003ctd\u003eSensor C: 0.3 to 6 kPa (3 to 60 mbar; 1.2 to 24 inH₂O)\u003cbr\u003eSensor F: 0.67 to 40 kPa (6.7 to 400 mbar; 2.67 to 160 inH₂O)\u003cbr\u003eSensor H: 2.67 to 160 kPa (26.7 to 1600 mbar; 10.7 to 642 inH₂O)\u003cbr\u003eSensor M: 10 to 600 kPa (0.1 to 6 bar; 1.45 to 87 psi)\u003cbr\u003eSensor N: 33.3 to 2000 kPa (0.33 to 20 bar; 4.83 to 290 psi)\u003cbr\u003eSensor S: 267 to 16000 kPa (2.67 to 160 bar; 38.7 to 2320 psi)\u003cbr\u003eMaximum span = URL. Minimum measuring span depends on the selected sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Signal\u003c\/th\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication Protocols\u003c\/th\u003e\n\u003ctd\u003eHART digital communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eOptional integrated digital LCD display; backlit LCD version available. D5 display option is marked PENDING in the ordering information.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Technology\u003c\/th\u003e\n\u003ctd\u003eDigital LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocal Operation\u003c\/th\u003e\n\u003ctd\u003eOptional 2-button keypad for local configuration. D1: LCD with 2-button keypad; D2: backlit LCD with 2-button keypad and enabled external pushbuttons.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectronics\u003c\/th\u003e\n\u003ctd\u003e4–20 mA with HART digital communication and Easy Set up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Block\u003c\/th\u003e\n\u003ctd\u003eThree connections for signal \/ remote display; suitable for wire cross-sections up to 2.5 mm² (14 AWG).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTurndown Ratio\u003c\/th\u003e\n\u003ctd\u003eUp to 60:1 for PDD300 diaphragm seal configurations. The achievable turndown depends on the selected sensor and diaphragm seal configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLong-Term Stability\u003c\/th\u003e\n\u003ctd\u003e±0.1% of URL over 10 years under standard operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Certification\u003c\/th\u003e\n\u003ctd\u003eOptional IEC 61508 SIL 2\/3 certification, ordering code GS. Certification and availability should be confirmed for the selected configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure Equipment Compliance\u003c\/th\u003e\n\u003ctd\u003ePressure Equipment Directive 2014\/68\/EU: Sound Engineering Practice (SEP).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eAvailable with direct-mounted or remote S26 diaphragm seals. Two-seal configurations include direct + remote or remote + remote arrangements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFeatures\u003c\/th\u003e\n\u003ctd\u003eDigital Advanced Diagnostics; S26 all-welded diaphragm seal construction; optional H-Shield diaphragm; configurable damping from 0 to 60 seconds; optional LCD display.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplications\u003c\/th\u003e\n\u003ctd\u003eIndustrial process pressure measurement; liquid, gas and steam pressure measurement; liquid level measurement in open tanks; applications requiring process isolation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess Connection\u003c\/th\u003e\n\u003ctd\u003eDepends on the selected S26 diaphragm seal model. Available seal connection types include ASME, EN and JIS flanged connections, wafer-type seals, threaded connections and sanitary \/ aseptic connections. Refer to the S26 data sheet for model-specific options.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Connection\u003c\/th\u003e\n\u003ctd\u003eTwo conduit entries: 1\/2 in–14 NPT or M20 × 1.5, depending on the selected housing configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWetted Materials\u003c\/th\u003e\n\u003ctd\u003eProcess isolating diaphragm: AISI 316L stainless steel (1.4435), Hastelloy C-276, gold-plated AISI 316L stainless steel or H-Shield AISI 316L stainless steel.\u003cbr\u003eProcess flanges, adapters, screw plugs and vent \/ drain valves: Stainless steel 316 \/ 316L or Hastelloy C-276, depending on configuration.\u003cbr\u003eGaskets: Viton or PTFE, where applicable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd\u003eAluminum alloy with epoxy finish or AISI 316L stainless steel. Electrical connection options include 1\/2 in–14 NPT or M20 × 1.5, depending on housing selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePDD300 Accuracy Details\u003c\/h3\u003e\n\u003cp\u003eThe specified accuracy depends on the selected sensor and diaphragm seal configuration. The following values are stated in the ABB Rev. J data sheet:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePDD300 seal configurations with mnemonic P3, F3, E3, S3 or F2:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSensor C: ±0.10% for TD 1:1 to 5:1; ±(0.02 × TD)% for TD 5:1 to 20:1.\u003c\/li\u003e\n\u003cli\u003eSensor F: ±0.055% for TD 1:1 to 10:1; ±(0.0055 × TD)% for TD 10:1 to 60:1.\u003c\/li\u003e\n\u003cli\u003eSensors H to S: ±0.075% for TD 1:1 to 10:1; ±(0.0075 × TD)% for TD 10:1 to 60:1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther PDD300 seal configurations:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSensor C: ±0.15% for TD 1:1 to 5:1; ±(0.03 × TD)% for TD 5:1 to 20:1.\u003c\/li\u003e\n\u003cli\u003eSensors F to S: ±0.10% for TD 1:1 to 10:1; ±(0.01 × TD)% for TD 10:1 to 60:1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe achievable accuracy depends on the selected sensor and S26 diaphragm configuration.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68240195944770,"sku":null,"price":1100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Differential_pressure_transmitter_with_diaphragm_seal_PDD300.png?v=1794984248","url":"https:\/\/antletstech.com\/ar\/products\/abb-differential-pressure-transmitter-with-diaphragm-seal-pdd300","provider":"ANTLETS","version":"1.0","type":"link"}