{"product_id":"abb-coriolis-mass-flowmeter-coriolismaster-fcb130","title":"ABB Coriolis mass flowmeter CoriolisMaster FCB130","description":"\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview \u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv class=\"sfContentBlock\"\u003e\n\u003cp\u003eWith no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.\u003cbr\u003e\u003cbr\u003eThe FCB130 series delivers: \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuperior accuracy and speed for filling applications\u003c\/li\u003e\n\u003cli\u003eFull parameter access with up to 115 kBaud \u003c\/li\u003e\n\u003cli\u003eAluminum housing or all stainless steel solution\u003c\/li\u003e\n\u003cli\u003eDTM based diagnostic and operability functions   \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe sensor delivers: \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultivariable measurement of mass flow, density and temperature in one device\u003c\/li\u003e\n\u003cli\u003eLow pressure drop save 25 % on pump energy costs compared to other brands\u003c\/li\u003e\n\u003cli\u003eWide measurement span in a single meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eThe ideal transmitter for system integration \u003c\/strong\u003e\u003cbr\u003e• Modbus for quick and comprehensive communication \u003cbr\u003e• Two fast digital outputs that can be configured as pulse outputs, \u003cbr\u003efrequency outputs or binary outputs \u003cbr\u003e• Lower pressure loss, self-draining \u003cbr\u003e• Global approvals for explosion protection \u003cbr\u003e• MID \/ OIML approval for legal metrology \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eIntegrated VeriMass device verification and diagnosis \u003c\/strong\u003e\u003cbr\u003e• Predictive maintenance in the process \u003cbr\u003e• Extended maintenance cycles \u003cbr\u003e• Reduced maintenance effort \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCoriolisMaster Software Tools \u003c\/strong\u003e\u003cbr\u003e• DensiMass for concentration measurements, net mass and volume flow calculations \u003cbr\u003e• FillMass for filling applications\u003c\/p\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFCB130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolisMaster Compact Coriolis Mass Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolis Mass Flow Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCoriolis Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured Media\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquids and Gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow, Volume Flow, Density and Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMass Flow and Volume Flow: ±0.4% of Rate (Optional ±0.25% of Rate); Density: ±10 g\/l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN15 to DN150 (1\/2 to 6 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDN15: 0 to 8,000 kg\/h; DN25: 0 to 35,000 kg\/h; DN50: 0 to 90,000 kg\/h; DN80: 0 to 250,000 kg\/h; DN100: 0 to 520,000 kg\/h; DN150: 0 to 860,000 kg\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Digital Outputs (Pulse, Frequency, Contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact Design with Aluminum or Stainless Steel Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Upstream or Downstream Straight Pipe Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel 1.4404 \/ 1.4435 (316L) or Hastelloy C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 to +160 °C (-58 to +320 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Pressure Drop Design for Energy-Efficient Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDTM-Based Diagnostics and Device Monitoring Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExplosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX Zone 0\/1\/2; cFMus Div. 1\/2 (Configuration Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact Design, High-Speed Measurement, Low Pressure Drop, Multivariable Measurement, Easy System Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFilling Systems, Chemical Processing, Food \u0026amp; Beverage, Pharmaceutical, Oil \u0026amp; Gas and General Industrial Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1 class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h1\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":56250669367618,"sku":null,"price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/9898\/7842\/files\/ABB_Coriolis_mass_flowmeter_CoriolisMaster_FCB130.png?v=1790217912","url":"https:\/\/antletstech.com\/ar\/products\/abb-coriolis-mass-flowmeter-coriolismaster-fcb130","provider":"ANTLETS","version":"1.0","type":"link"}